Actions – HP NonStop G-Series User Manual
Page 141
Rail Maximum Voltage
The maximum voltage limit (60 volts) for the CRU.
Other Rail Voltage After Fuse
The current voltage on the Other Rail of the PMF2 CRU, measured
after the fuse.
DCC Voltage
The operational voltage of the PMF or IOMF2 CRU (specifically,
the raw voltage supplied to the DC-to-DC converters).
Other Rail Voltage
The voltage of the Other Rail, which connects the PMF/IOMF CRU
to the other power supply in the enclosure (to provide power in the
event of a problem with the Main Rail power supply).
Storage ASIC
Initialization State
The status of the storage ASIC in the CRU.
Values: Initialized, Uninitialized, Unknown
Actions
Disable ServerNet Port
Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number
Enable ServerNet Port
Enables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number
Force Power Off
This action is not supported for this CRU type. See the
action.
Power Off
This action is not supported for this CRU type. See the
action.
Prepare to Power Off
Performs precautionary check to make sure that you can safely remove the CRU.
The precautionary check makes sure that the other IOMF2 CRU in this enclosure exists and is
powered on.
If the check confirms that you can safely power off the CRU, these preparatory steps are performed:
If the SP on this IOMF2 is designated as Active (Primary), resets the SP so that the peer SP
●