64

Installation

Step 4: Configure LCCs

The disk system comes with two LCCs installed.

If you are connecting this disk system to an HP StorageWorks Virtual Array 7400
or to a 1 Gb/s hub, the link speed switch must be set to 1 Gb/s.

1

Attach your ESD strap to ground.

2

Remove the LCC from the disk system chassis.

Caution

Do not touch the pins on the back of the LCC.

3

Set internal configuration dip switch to appropriate link speed.

Be sure to set the internal LCC data transmission speed switch to 1
Gb/s or 2 Gb/s as appropriate for your configuration. See Figure 2.29
for more detailed information.