Software requirements, Software requirements 37 – HP StorageWorks 2405 Disk System User Manual
Page 37

Installation
37
In
st
al
la
ti
o
n
Software Requirements
Ensure that the minimum revisions of HP-UX extension software and online
diagnostics are installed. These release packages enable STM and EMS for the
disk system.
1
At the host console, enter
swlist | grep XSW
and look for the following
extension software according to the installed HP-UX revision:
—
HP-UX 11.00 with HWE 0302 (March 2002 Patch bundles)
—
HP-UX 11.11 with HWE 0302 (March 2002 Patch bundles)
2
Enter
swlist | grep Online
and look for the following online
diagnostics according to the installed HP-UX revision:
—
OnlineDiags B.11.00.20.09
, or greater, on HP-UX 11.00
—
OnlineDiags B.11.11.06.09
, or greater, on HP-UX 11.11
If swlist does not report the specified releases, install them from the latest
CD-ROM in any of the following products:
—
For HP-UX 11.00:
o B3920EA HP-UX OE Media for Servers
o B6261AA HP-UX 11.00 Extension Upgrade Media Kit
—
For HP-UX 11.11:
o B3920EA HP-UX OE Media for Servers
o B6191AA HP 9000 Support Plus Media
o B6821AA HP-UX TCOE Media
o B6845AA HP-UX 11.11 Minimal Technical OE Media
o B7993AA HP-UX Enterprise OE Server Media
o B7994AA HP-UX Mission Critical OE Comm. Media
The external IT Resource Center web site is:
http://us-support3.external.hp.com/