Troubleshooting

103

T

roub
le

shoo

ting

4

After the device files have been created, issue the FCMSUTIL command on
the device files. For example:

/opt/fcms/bin/fcmsutil /dev/fcms0

The output should appear similar to the following:

Local N_Port_ID is = 0x000001

N_Port Node World Wide Name = 0x10000060B03E22CB

N_Port World Wide Name = 0x10000060B03E22CB

Topology = IN_LOOP

Speed = 1062500000 (bps)

HPA of card = 0xFBF48000

EIM of card = 0xFFFA000A

Driver state = Ready

Number of EDB’s in use = 0

Number of OIB’s in use = 0

Number of Active Outbound Exchanges = 1

Number of Active Login Sessions = 5

A driver state of Ready indicates that the driver is in the correct operating
state. IN_LOOP topology indicates that the host has detected an FC-AL.

5

Check Fibre Channel cables for loose connections.

6

Check the Enclosure ID switches for conflicting loop IDs. Make sure both
LCCs have the same ID setting.