HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 27
Troubleshooting 27
Error code
Details
VCSU_ERROR_PRIMARY_BACKUP_HEALTH_NOT_OK
The health of primary or standby module is not
OK. The update cannot proceed.
VCSU_ERROR_MIN_TARGET_VERSION_ROLLBACK_
DOWNGRADE
The target version does not support the
downgrade of Virtual Connect firmware without
deletion of domain configuration.
VCSU_ERROR_MIN_VCM_VERSION_ROLLBACK_
DOWNGRADE
The current version of Virtual Connect firmware
does not support the downgrade without
deletion of domain configuration.
VCSU_ERROR_PRIMARY_NOT_IN_LOWER_BAY_FOR_
DOWNGRADE
Presence of subordinate module on lower bay
before primary module will not allow
downgrade.
VCSU_ERROR_ROLLBACK_DOWNGRADE_WILL_NOT_
PROCEED_FOR_MANUAL_ENET_ACTIVATION
Rollback downgrade will not proceed for
manual activation of E-net modules.
VCSU_ERROR_VCM_LOCKED_BY_VCEM_AND_FW_
MAINTENANCE_MODE
VC is locked by VCEM Firmware Maintenance
mode. Downgrade will not proceed.
VCSU_ERROR_ROLLBACK_DOWNGRADE_WILL_NOT_
PROCEED_FOR_SERVERPOWERON_NOSAFE
Powered ON servers or server profile migration
since upgrade and performing downgrade may
result in duplicate MAC/WWN in the domain.
Power OFF the servers to avoid the
MAC/WWN duplication and perform the
downgrade.
VCSU_ERROR_ROLLBACK_FAILED_TO_ACTIVATE_
LOWEST_BAY
Failed to activate lowest E-net bay for rollback
VCSU_ERROR_ROLLBACK_FAILED_TO_ACTIVATE_ODDSIDE
_MODULE
Failed to activate odd side modules for rollback
VCSU_ERROR_ROLLBACK_ACTIVATE_FAILURE
Rollback activation failed
VCSU_ERROR_ROLLBACK_ODDMODULE_MANAGED_
STATUS_NOT_NORMAL
Odd module managed status is not Normal.
VCSU_ERROR_ADD_USER_FAILED
Unable to add user
VCSU_ERROR_REMOVE_USER_FAILED
Unable to remove user
VCSU_ERROR_SET_NAME_FAILED
Unable to set the user name
VCSU_ERROR_AND_EXIT_FROM_UPDATE
Fatal error. One or more modules is preventing
VCSU from continuing. Correct conditions listed
above and retry.
VCSU_ERROR_MODULE_FAILOVER_FAILED
Module did not come up with proper role after
failover.
VCSU_ERROR_FIRMWARE_EXTRACT_FAILED
Failed to extract the VC firmware package
VCSU_ERROR_GET_ENCLOSURE_INFORMATION_FAILED
Failed to get enclosure information
VCSU_ERROR_SET_TO_SLAVE_FAILED
Failed to set the module to subordinate state
VCSU_ERROR_SET_TO_AUTO_FAILED
Failed to set the module to auto state
VCSU_ERROR_VC_LOGIN_FAILED
Failed to log in to Virtual Connect
VCSU_ERROR_ADD_VCM_USER_FAILED
Failed to add VC user in Onboard
Administrator
VCSU_ERROR_PRIMARYMODULE_BEING_IN_EVENBAY_
AND_NO_BACKUP_MODULE
Rollback will not proceed since primary module
is in even bay and there is no backup module.
VCSU_ERROR_RESOLVE_HOST_INFO_FAILED
Failed to resolve the hostname
VCSU_ERROR_VCM_SKIP_FAILOVER
Virtual Connect does not have a valid Backup
module. Cannot failover.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem