beautypg.com

Update – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 15

background image

Commands 15

Item

Description

Connect domain. Minimum length is 1 character. Maximum length is 31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31

characters.

LOCATION

Full path, including file name, to save the support dump file. If not provided, VCSU saves the

support dump file to the file name that VC provides and downloads it to the current directory.

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across

local and all remote enclosures in the Virtual Connect domain.

Example
Save support information:

vcsu -a supportdump -i 192.168.0.100 -u Administrator -p password -vcu

Administrator -vcp password

update

Update the firmware.
You must provide the primary OA IP address, user credentials, and the package file to use for the update.
You can force a module update in the following circumstances:

The target module contains a running firmware image that is the same version as the one in the source

package.

The target module is in a degraded or failed state.

If some of the modules are powered off, you can use the force option to update the modules that are

powered on.

Item

Description

Syntax

vcsu -a update -i -u -p -l [-f ] -vcu

-vcp [-q] [-oe ] [-of ] [-we

] [-wf ] [-cp ]

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum
length is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40

characters.**

FILE

Full path to the Virtual Connect package on the local computer or supported remote server

FORCE

Optional. Comma-separated list of force operations under certain conditions:

version—Allows an update of the same firmware version

health—Allows an update on a module with failed or degraded health

VCM USER

Name of the Virtual Connect user with Domain privileges. This command is required if an

enclosure is in a Virtual Connect domain. Minimum length is 1 character. Maximum length is
31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31

characters.

-q

Optional. Specifies that the firmware update does not prompt for confirmation before
updating, and uses the default answer for the confirmation (YES).

-oe

Optional. Specifies VC-Enet module activation order. The following activation order methods