HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 25
Troubleshooting 25
Error code
Details
VCSU_ERROR_RESET_FAILED
The reset on the target module failed.
VCSU_ERROR_INVALID_MODULEID
The specified module ID is invalid.
VCSU_ERROR_PREVIOUS_UPDATE_NOT_COMPLETETD
A previous firmware update operation on one
or more modules is not complete.
VCSU_ERROR_MULTIPLE_INSTANCE
Another firmware update is running against the
specified OA.
VCSU_ERROR_FC2_FW_EXTRACTION_FAILED
The extraction of the VC FC2 firmware package
failed.
VCSU_ERROR_DOWNGRADE_FROM_MULTIENCLOSURE
A downgrade from a 2.10 multi enclosure
domain is not supported.
VCSU_ERROR_NOT_MULTIENCLOSURE
Invalid module IDs for single enclosure update
VCSU_ERROR_VCM_MODE_RESTORE_FAILED
Failed to restore the VC mode of primary or
backup module
VCSU_ERROR_ACTIVATION_FAILED
Failed to activate one or more modules
VCSU_ERROR_UNINITIALIZED_MUTEX
Invalid mutex found
VCSU_ERROR_MODULE_NOT_FOUND
The specified module is not found at remote
endpoint.
VCSU_ERROR_DOWNGRADE_VCENET_VERSION
Internal Error: A downgrade from this version of
Virtual Connect firmware to the target version
would result in destruction of the domain.
Manually delete the Virtual Connect domain
and run the Virtual Connect Support Utility
again.
VCSU_ERROR_UNSUPPORTED_RESET_MODE
The specified reset mode is not supported.
VCSU_ERROR_CGI_FAILED
The specified CGI operation failed. Try the
operation again.
VCSU_XML_PARSING_FAILED
XML parsing of the description file failed.
VCSU_XML_FILE_EMPTY
The XML file is empty.
VCSU_XML_INVALID_FILE
The XML file format is invalid.
VCSU_ERROR_PRIMARY_VCM_IP_NOT_FOUND
Could not get the Primary VC module IP address
VCSU_ERROR_PRIMARY_VCM_NOT_FOUND
Could not find the Primary VC module
VCSU_ERROR_INVALID_HTTP_RESPONSE
Invalid HTTP response
VCSU_ERROR_UNKNOWN_HTTP_ERROR
Unknown HTTP error
VCSU_ERROR_HTTP_GET_ERROR
HTTP GET failed
VCSU_ERROR_HTTP_ERROR
The HTTP method returned an error. Check the
log for error details.
VCSU_ERROR_FILE_EXTRACT_FAILED
The specified firmware file could not be
extracted.
VCSU_ERROR_MODULE_IMAGE_INFO_NOT_AVAILABLE
The image information for the specified module
type is not available in the package.
VCSU_ERROR_FW_SIGNATURE_VERIFICATION_FAILED
The signature verification of the specified
package failed.
VCSU_ERROR_HEALTH_NOT_OK
The health of the module is not in a good state.
VCSU_ERROR_POWER_NO_OP
No Op
VCSU_ERROR_POWER_UNKNOWN
Unknown
VCSU_ERROR_POWER_OFF
Off
VCSU_ERROR_POWER_STAGED_OFF
Staged Off
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem