beautypg.com

Downgrades, Overview, Restrictions – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 18

background image

Downgrades 18

Downgrades

Overview

This feature enables you to downgrade to a previously installed and running version of VC.
The following requirements are for downgrading firmware on a VC domain without destroying the domain.
Otherwise, to downgrade firmware on VC modules, you must first delete the domain and then use the -a

update command.

Restrictions

The following restrictions apply:

You must be running VC version 3.70 or higher to perform a downgrade.

You cannot downgrade to a VC version lower than version 3.17.

A previous upgrade must have been performed on the configuration using VCSU 1.7.0 or higher.

All servers in the domain must be powered off.

Multiple, consecutive firmware downgrades are not allowed.

You can downgrade only to the version previously installed and running on the primary module.

The VC configuration, including physical connections, uplink port connections, and module positions in
the enclosure, must be identical to the target downgrade configuration.

The VC credentials must be the same before and after the downgrade. After the downgrade, you cannot
change the password for the account used to perform the downgrade.

The primary E-net module must be in the lowest bay number.