Commands 10

Commands

collect

Contact the OA using the supplied credentials and execute a SHOW ALL from the OA CLI, saving the output

to an "oaShowAll.txt" file in the current directory.
This support action also contacts the primary VC module using the supplied credentials and executes the

following commands, saving the output to a "vcmShowAll.txt" file:

show enclosure *

show domain

show network *

show fabric *

show profile *

show stackinglink

show interconnect *

show firmware

Item

Description

Syntax

vcsu -a collect -i -u -p -vcu -vcp

PASS>

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum

length is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40

characters.**

VCM USER

Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual

Connect domain. Minimum length is 1 character. Maximum length is 31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31
characters.

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across

local and all remote enclosures in the Virtual Connect domain.

Example
Collect configuration information from OA and VC:

vcsu -a collect -i 192.168.0.100 -u Administrator -p password -vcu

Administrator -vcp password