beautypg.com

Resetvcm, Supportdump – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 14

background image

Commands 14

Item

Description

FILE

Full path to the Virtual Connect package on the local computer or supported remote server

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across

local and all remote enclosures in the Virtual Connect domain.

Example
Display all modules in an enclosure:

vcsu -a report -i 192.168.1.100 -u Administrator -p password -vcu

Administrator -vcp password -l VCpackage

resetvcm

Log in to the specified interconnect bay and restart the Virtual Connect service. This action is equivalent to

selecting the "Reset Virtual Connect Manager" option from the Tools pull-down menu on the Virtual Connect

GUI.

Item

Description

Syntax

vcsu -a resetvcm -i -u -p

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length

is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40

characters.**

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.

Example
Reset the modules in an enclosure:

vcsu -a resetvcm -i 192.168.0.100 -u Administrator -p password

supportdump

Using the supplied credentials, log in to Virtual Connect and request a support information (debug dump)

download. VCSU saves the file in the current directory using the file name supplied by Virtual Connect. This

action requires a functioning VC domain.

Item

Description

Syntax

vcsu -a supportdump -i -u -p -vcu -vcp

PASS> -l

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length

is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**

VCM USER

Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual