Commands 12

Request a configuration download from Virtual Connect:

vcsu -a configbackup -i 192.168.0.100 -u Administrator -p password -vcu

Administrator -vcp password

healthcheck

List the state of modules in the enclosure. This command is useful if an Administrator needs to know if

performing an action, such as a failover or a VC or OA firmware upgrade, would cause an outage.
On an enclosure configured for Virtual Connect, the command displays the following:

Onboard Administrator firmware version

Power: On, Off, other

Health: OK, Degraded, Failed, other

IP Address

Connectivity Test

For VC-Enet Modules:

o

VC Mode: Primary, Backup, Subordinate, Unintegrated

o

Module Configuration: In Sync, Not In Sync, Invalid

o

Domain Configuration (for primary or backup VC-Enet modules): In Sync, Not In Sync

The primary Virtual Connect module saves the domain configuration data to the backup module in a VC

domain at a regular interval. The 'Domain configuration' state indicates whether or not this data is in sync
between the two modules.
The 'Module configuration' state indicates whether all the modules in an enclosure are in sync with the

primary module regarding the Virtual Connect configuration information.
If a module is being reconfigured by Virtual Connect, or is rebooting, a "Not In Sync" or "Invalid"
configuration status might appear. Wait up to 2 minutes, and then execute the healthcheck command

again.

Item

Description

Syntax

vcsu -a healthcheck -i -u -p -vcu -vcp

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum

length is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40

characters.**

VCM USER

Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual
Connect domain. Minimum length is 1 character. Maximum length is 31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31

characters.

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.

Example