HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 16

background image

Commands 16

Item

Description

are supported:

parallel—All modules are activated at the same time.

odd-even—(Default) The backup VC module is activated first. A force failover to the

backup module occurs, and then the primary module is activated. The modules in odd

bays are activated, and then modules in even bays are activated.

serial—The backup VC module is activated first. A force failover to the backup module

occurs, and then the primary module is activated. A checkpoint is completed between the

primary and standby module. Then the remaining modules are activated one at a time,
starting with the lowest numbered bay.

manual—Modules are updated but not activated. Use the VC GUI or the OA GUI to

activate (reboot) modules.

-of

Optional. Specifies VC-FC module activation order. The following activation order methods

are supported:

parallel—All modules are activated at the same time.

odd-even—All modules in odd-numbered bays are activated first, and then modules in

even-numbered bays are activated.

serial—(Default) Modules are activated one at a time, starting with the lowest

numbered bay.

manual—Modules are updated but not activated. Use the OA GUI to activate (reboot)

modules.

-we

Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting

VC-Enet modules. This command is required for some MPIO/teaming software on the server
blades in the enclosure. The default is 0, or no delay. HP recommends a minimum of 5

minutes.

-wf

Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting

VC-FC modules. This command is required for some MPIO/teaming software on the server
blades in the enclosure. The default is 0, or no delay. HP recommends a minimum of 5

minutes.

-cp

Optional. Password for the configuration backup file. Supported in VC firmware versions

3.00 and higher. The default is no password.

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across

local and all remote enclosures in the Virtual Connect domain.

Examples
Update multiple modules in an enclosure imported into a VC domain:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp

vcPass -l C:\images\vcfw-120.bin

Perform an update and specify an activation ordering method:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp

vcPass -l C:\images\vcfw-120.bin -oe serial -of parallel

Perform an update using a firmware image from a web server address:

vcsu –a update –i 192.168.1.100 –u Administrator –p password –l

http://www.myserver.com/vcfw-120.bin

Perform an update using a firmware image from an FTP server on the network:

vcsu –a update –i 192.168.1.100 –u Administrator –p password –l

ftp://user:[email protected]/vcfw-120.bin

Perform an update of the same firmware version on a degraded module: