beautypg.com

Packageinfo, Report – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 13

background image

Commands 13

List the state of modules in an enclosure:

vcsu -a healthcheck -i 192.168.0.100 -u Administrator -p password -vcu

Administrator -vcp password

packageinfo

Extract the package information from the supplied package path and display the following information:

Digital Signature Validation (for Virtual Connect firmware version 2.30 and higher)

Package Version

Ethernet Firmware Version Timestamp

Ethernet Firmware Supported Hardware

FC Firmware Version

FC Firmware Supported Hardware

Release Notes (extract, not display)

Item

Description

Syntax

vcsu -a packageinfo -l

Parameter:

FILE

Full path to the Virtual Connect package on the local computer or supported remote server

Example
Display package information from a file named VCpackage:

vcsu -a packageinfo -l VCpackage

report

Display the current running firmware version on all modules in a specific target enclosure. Also display the

VC-Enet and VC-FC firmware versions provided in the specified VC package file, and whether or not the

module can be updated. In addition to displaying the module firmware version and status, the report

command also displays details about the VC package contents.
Because the package version details appear, you must provide a VC package file as part of the input at the

command line.

Item

Description

Syntax

vcsu -a report -i -u -p -vcu -vcp

-l

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length

is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40

characters.**

VCM USER

Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual
Connect domain. Minimum length is 1 character. Maximum length is 31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31

characters.