beautypg.com

HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 23

background image

Troubleshooting 23

Error code

Details

VCSU_ERROR_SSH_SESSION_NOT_ESTABLISHED

The SSH session is not established.

VCSU_ERROR_SSH_INVALID_COMMAND

Invalid SSH command

VCSU_ERROR_SFTP_SHUTDOWN_FAILED

Failed to shut down SFTP

VCSU_ERROR_INVALID_IP_ADDRESS

Invalid IP address.

VCSU_ERROR_CONNECT_FAILED

Socket or connection call to the specified IP

failed.

VCSU_ERROR_OA_COMMUNICATION_FAILED

Unable to communicate using the given OA IP

VCSU_ERROR_GET_HOST_INFO_FAILED

Unable to retrieve host information from the

given IP

VCSU_ERROR_INVALID_OA_USERNAME

Invalid OA user name

VCSU_ERROR_INVALID_OA_PASSWORD

Invalid OA password

VCSU_ERROR_INVALID_BAY_NUMBER

Invalid bay number

VCSU_ERROR_OA_INIT_FAILED

OA Initialization failed.

VCSU_ERROR_OA_LOGIN_FAILED

OA login failed.

VCSU_ERROR_OA_LOGOUT_FAILED

OA logout from the current user failed.

VCSU_ERROR_OA_GET_NETWORK_INFO_FAILED

Could not get network information from either

Onboard Administrator

VCSU_ERROR_OA_FW_VERSION_NOT_SUPPORTED

OA firmware version is not supported without

force.

VCSU_ERROR_OA_FW_VERSION_SUPPORTED_WITH_
FORCE

OA firmware version is not supported without

force.

VCSU_ERROR_OA_SOAP_CALL_FAILED

Communication to OA using SOAP failed.

VCSU_ERROR_VC_SOAP_CALL_FAILED

Communication to VC using SOAP failed.

VCSU_ERROR_OA_NOT_PRIMARY

The specified OA is not primary.

VCSU_ERROR_OA_GET_VCM_MODE_FAILED

Unable to retrieve OA VC mode information

VCSU_ERROR_OA_INTERNAL_PASSWD_INVALID

The OA internal password length is invalid.

VCSU_ERROR_INVALID_INFOBLOCK_FROM_OA

Invalid Info block from OA is received.

VCSU_ERROR_VCM_ACCESS_INFO_EXTRACTION_FAILED Unable to extract VC access information
VCSU_ERROR_UNSUPPORTED_ENCLOSURE

The specified enclosure is not supported.

VCSU_ERROR_VCFC_NOT_RESPONDING

The VC FC module is not responding.

VCSU_ERROR_VENDOR_INFOBLOCK_RETURNED_ERROR

Vendor Info block returned an error.

VCSU_ERROR_BAY_INFO_RETRIEVAL_FAILED

Unable to retrieve information from the

interconnect module at the specified bay

VCSU_ERROR_NOT_PRIMARY_ENCLOSURE

The specified enclosure is not primary in the
domain.

VCSU_ERROR_PRIMARY_ENCLOSURE_NOT_FOUND

Failed to get Primary Enclosure information.

VCSU_ERROR_ENCLOSURE_NOT_IMPORTED

The specified enclosure is not imported in the

domain.

VCSU_ERROR_PRIMARY_OA_NOT_FOUND

Unable to find the Primary OA IP

VCSU_ERROR_BAY_COMMUNICATION_FAILURE

Unable to communicate with the interconnect
module in the specified bay

VCSU_ERROR_VCME_DOMAIN

VC ME domain

VCSU_ERROR_VCEM_DOMAIN

This VC domain is being managed by an

external manager. See the external manager
documentation for instructions on firmware

updates.