A - 12 APPENDIX (SPECIFICATIONS, FONTS AND BAR CODE)
■
When Codebar is chosen with the parameter 't9' or 'T9'
Characters '0' to '9', '-', ' . ', '$', '/', '+', ' : ' can be printed. Characters 'A' to 'D' can be printed as a start-stop
code, which can be upper case or lower case. If there is no start-stop code, errors will happen. A check
digit cannot be added and using '?' causes errors.
■
When Code 128 Set A, Set B, or Set C is selected with the parameter 't12' or 'T12,' 't13' or 'T13,' or
't14' or 'T14'
Code 128 sets A, B and C can be individually selected. Set A indicates characters Hex 00 to 5F. Set B
includes characters Hex 20 to 7F. Set C includes the pairs 00 to 99. Switching is allowed between the
code sets by sending %A, %B, or %C. FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4. The
SHIFT code, %S, allows temporary switching (for one character only) from set A to set B and vice versa.
The '%' character can be encoded by sending it twice.
■
When ISBN (EAN) is selected with the parameter 't130' or 'T130'
The same rules apply as for 't5' or 'T5'.
■
When ISBN (UPC-E) is selected with the parameter 't131' or 'T131':
The same rules apply as for 't6' or 'T6'.
■
When EAN 128 set A, set B or set C is selected with the parameter 't132' or 'T132', 't133' or 'T133'
or 't134' or 'T134'
The same rules apply as for 't12' or 'T12', 't13' or 'T13', or 't14' or 'T14'.
Box drawing
ESC i ... E (or e)
'E' or 'e' is a terminator.
Line block drawing
ESC i ... V (or v)
'V' or 'v' is a terminator.