4 class 05 – devicenet connection object, 5 class 40 (28hex) – motor data object, 5 class 40 (28 – NORD Drivesystems BU0080 User Manual
Page 40: Motor data object

NORDAC DeviceNet Manual
40
BU
0080
GB
6.5.4
Class 05 – DeviceNet Connection Object
The settings for each active connection can be read out in this object:
Instance 1: Expl.Message
Instance 2: Polling
Instance 3: Bit-Strobe
Instance 4: COS/Cyclic
Inst Attr.
Description
Type
Access
1 State
USINT
Get
2 Instance
Type
USINT
Get
3 transportClass_trigger
BYTE
Get
4 produced_connection_id
UINT
Get
5 consumed_connection_id
UINT
Get
6 initial_comm_characteristic
BYTE
Get
7 produced_connection_size
UINT
Get
8 consumed_connection_size
UINT
Get
9 expected_packet_rate
UINT
Get/Set
12 watchdog_timeout_action
USINT
Get
13 produced_con_path_length
UINT
Get
14 produced_connection_path EPATH
Get
15 consumed_con_path_length
UINT
Get
16 consumed_connection_path EPATH
Get
1-4
17 produced_inhibit_time
UINT
Get
6.5.5
Class 40 (28
hex
) – Motor Data Object
Motor-specific data can be set or read via the Motor Data Object. This object is only valid if the AC Profile is
switched on (see above)!
Inst Attr.
Description
Type
Access
3 Motor
type
USINT
Get
6 Stator current [0.1A]
UINT
Get
7 Rated voltage [V]
UINT
Get/Set
8 Rated motor power [W]
UDINT
Get/Set
9 Nominal
frequency
UINT
Get/Set
1
12 Number of poles
UINT
Get