beautypg.com

FUTEK IPM500 (D500) Digital Display User Manual

Page 51

background image

- 51 -

Form A, SPST Solid State Relay Output:
AC Rating..................................................................................................130 mA @ 140 Vac
DC Rating..................................................................................................130 mA @ 180 Vdc
Isolation rating between signal common and contacts ............................................... 250V ac
Insulation dielectric strength between signal common and contacts ........................................

................................................................................... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min

Analog Output Option

Power to Analog Output Option...................................................................Powered by meter
Output Levels ..............................................................0-20 mA, 4-20 mA, 0-10V, -10 to +10V
Voltage Compliance, 0-20 mA Output .................................................. 12V (0-600 Ohm load)
Current Compliance, 0-10V, -10 to +10V Output.......................2 mA (5 kOhm or higher load)
Accuracy ..........................................Meter input accuracy ±0.02% of full scale analog output
Resolution ...........................................................................................16 bit (1 part in 65,536)
Response Time ....................................................................................... 50/60Hz update rate
Scaling of Reading for Zero Output ............................................................-99,999 to +99,999
Scaling of Reading for Full Scale Output................................................... -99,999 to +99,999
Isolation rating between signal common and analog output....................................... 250V ac
Insulation dielectric strength between signal common and analog output................................

................................................................................... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min

Serial Interface Option

(USB, RS232, RS485, RS485-Modbus boards)

Output Types................................................................RS232, RS485, RS485-Modbus, USB
Power to Interface Option............................................................................Powered by meter
RS485 Wiring ............................................................................................... Half or full duplex
Baud Rates ............................................................ 300, 600, 1200, 2400, 4800, 9600, 19200
Serial Protocols ............................. Custom ASCII, Modbus RTU, Modbus ASCII (selectable)
Signal Levels .............................................................................. Meet RS232, RS485 or USB
Connectors....... USB, Single RJ11 (RS232), two RJ11 (RS485), two RJ45 (RS485-Modbus)
Isolation rating between signal common and serial I/O .............................................. 250V ac
Insulation dielectric strength between signal common and serial I/O .......................................

................................................................................... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min

Environmental

Operating Temperature .........................................................................................0°C to 55°C
Storage Temperature ........................................................................................ -40°C to 85°C
Relative Humidity ...................................................... 95% from 0°C to 40°C, non-condensing
Case............................ NEMA-4X (IP65) from front when panel mounted (not verified for UL)
Shock ........................................................................... 10 G at 1 kHz, applied in X, Y, Z axes
Vibration ............................................. 15 Hz to 150 Hz, 1 mm to 2 mm amplitude, 20 G max.

This manual is related to the following products: