Dwyer 32DZ User Manual
Page 22
949-1318
Page 22 of 40
June, 2000
center of the proportional band, a pulse
value of 1 provides an output of one sec-
ond on and one second off (50% output). A
pulse value of 2 provides an output of one
second on and two seconds off (33% out-
put). Output at center of band equals one
second on, 2
(pulse value-1)
seconds off.
ProP
For Current (Code 5) outputs only.
tun2
tun2
tun2
tun2
tun2
Tuning Choice: Select
SELF
SELF
SELF
SELF
SELF
,
Pid
Pid
Pid
Pid
Pid
,
SLO
SLO
SLO
SLO
SLO
,
nor
nor
nor
nor
nor
, or
FASt
FASt
FASt
FASt
FASt
.
SELF
SELF
SELF
SELF
SELF
The Controller will evaluate the Process and se-
lect the PID values to maintain good control.
Lrn2
Lrn2
Lrn2
Lrn2
Lrn2
Select
YES
YES
YES
YES
YES
or
no
no
no
no
no
YES
YES
YES
YES
YES
Start Learning the Process. After
the process has been learned the
menu item will revert to
no
no
no
no
no
.
no
no
no
no
no
Learning will stay in present mode.
dFC2
dFC2
dFC2
dFC2
dFC2
Damping factor, Select
OFF
OFF
OFF
OFF
OFF
,
1
11
11
to
7
77
77
. Sets
the ratio of Rate to Reset for the
SELF tunE
mode.
7
77
77
= most Rate. Factory set to
3
33
33
. For
a fast response process the value should
be lowered (less Rate). For a slower pro-
cess the value should be increased (more
Rate).
Pid
Pid
Pid
Pid
Pid
Manually adjust the PID values. PID control con-
sists of three basic parameters, Proportional Band
(Gain), Reset Time (Integral), and Rate Time
(Derivative).
Pb2
Pb2
Pb2
Pb2
Pb2
Proportional Band (Bandwidth). Select
1
11
11
to
9999
9999
9999
9999
9999
°F, °C, or counts.
rES2
rES2
rES2
rES2
rES2
Automatic Reset Time. Select
OFF
OFF
OFF
OFF
OFF
,
0.1
0.1
0.1
0.1
0.1
to
99.9
99.9
99.9
99.9
99.9
minutes. Select
OFF
OFF
OFF
OFF
OFF
to switch to
OFS2
OFS2
OFS2
OFS2
OFS2
.
OFS2
OFS2
OFS2
OFS2
OFS2
Manual Offset Correction Select
OFF
OFF
OFF
OFF
OFF
,
0.1
0.1
0.1
0.1
0.1
to
99.9
99.9
99.9
99.9
99.9
%. Select
OFF
OFF
OFF
OFF
OFF
to switch to
rES2
rES2
rES2
rES2
rES2
.
rtE2
rtE2
rtE2
rtE2
rtE2
Rate Time. Select
OFF
OFF
OFF
OFF
OFF
,
0.01
0.01
0.01
0.01
0.01
to
99.99
99.99
99.99
99.99
99.99
min-
utes, Derivative.
SLO
SLO
SLO
SLO
SLO
PID values are preset for a slow response pro-
cess.
nor
nor
nor
nor
nor
PID values are preset for a normal response
process.
FASt
FASt
FASt
FASt
FASt
PID values are preset for a fast response process.
ArS2
ArS2
ArS2
ArS2
ArS2
Anti- Reset Windup Feature: Select
On
On
On
On
On
or
OFF
OFF
OFF
OFF
OFF
.
On
On
On
On
On
Reset Offset value will be cleared to 0% when the
process input is not within the Proportional Band.