beautypg.com

KROHNE IFC 010 Converter EN User Manual

Page 13

background image

2/2

Connection diagrams for outputs 2.3

Milliammeter

Totalizer
– electronic (EC)
– electromechanical (EMC)

1

2

3

4

I

= 0/4 - 20 mA

U

ext

15...20 V DC 20...32 V DC

R

i

0...500

250...750

U

ext

15 V DC

I

= 0/4 - 20 mA

R

i

500

Stromausgang
I

active

Stromausgang
I

passive

6

5

Pulse output P

passive

for electronic (EC) or
electromechanical (EMC) totalizers

U

ext

32 V DC/

24 V AC

I

max

150 mA

(incl. status output)

U

int

15 V DC from current output

Operation with current output:
I

max

3 mA

Operation without current output:
I

max

23 mA

R

15 V

I

max

U

ext

U

ext

DC voltage,
external power source (U

ext

),

note connection polarity

External voltage source (U

ext

),

DC or AC voltage,
connection polarity arbitrary

Active mode

The current output supplies the power for
operation of the outputs.

Passive mode

External power source required for operation of
the outputs.

I

max

Status output S

passive

U

ext

32 V DC/

24 V AC

I

max

150 mA

(incl. pulse output)

Pulse output P

active

(and current output I

active

)

for electronic (EC) totalizers
with and without current output I

Status output S

active

with and without current output I

U

int

15 V DC

from current output

I

max

3 mA

Operation with
current output

I

max

23 mA

Operation without
current output

Load

Load