TECHNICAL DATA

8

75

H250 M40

www.krohne.com

11/2012 - 4000640702 MA H250 M40 R02 en

H250H - Horizontal installation position

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:
Flow measurements for gases are attributed to
Nl/h or Nm

3

/h: Volume current in standard state 0°C - 1.013 bar abs. (DIN 1343)

Measuring span:

10 : 1

Flow values:

Values = 100%

Water 20°C / 68°F

Air: 20°C [68°F], 1,013 bar abs. [14,7 psia]

EN

ASME

Cone

Water [l/h]

Air [Nm

3

/h]

Pressure loss

[mbar]

DN15

½

K 15.1

70

1.8

195

K 15.2

120

3

204

K 15.3

180

4.5

195

K 15.4

280

7.5

225

K 15.5

450

12

250

K 15.6

700

18

325

K 15.7

1200

30

590

K 15.8

1600

40

950

K 15.8

2400

60

1600

DN25

1"

K 25.1

1300

35

122

K 25.2

2000

50

105

K 25.3

3000

80

116

K 25.4

5000

130

145

K 25.5

8500

220

217

K 25.5

10000

260

336

DN50

2"

K 55.1

10000

260

240

K 55.2

16000

420

230

K 55.3

22000

580

220

K 55.3

34000

900

420

DN80

3"

K 85.1

25000

650

130

K 85.2

35000

950

130

K 85.2

60000

1600

290

DN100

4"

K 105.1

80000

2200

250

K 105.1

120000

3200

340

INFORMATION!
The operating pressure should be at least double the pressure loss for liquids and five times for
gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other
flow ranges on request. Conversion of other media or operating data is performed using the
calculation method in accordance with VDI /VDE Directive 3513.

MA_H250_M40_R02_en_640702_PRT.book Page 75 Wednesday, November 28, 2012 12:23 PM