TECHNICAL DATA

8

71

H250 M40

www.krohne.com

11/2012 - 4000640702 MA H250 M40 R02 en

8.4 Measuring ranges

H250/RR - Stainless Steel, H250/HC - Hastelloy

®

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:
Flow measurements for gases are attributed to
Nl/h or Nm

3

/h: Volume current in standard state 0°C - 1.013 bar abs. (DIN 1343)

Measuring span:

10 : 1

Flow values:

Values = 100%

Water 20°C / 68°F

Air: 20°C [68°F], 1,013 bar abs. [14,7 psia]

Water

Air

Max. pressure loss

Float

TIV

CIV

DIV

TIV

Alu

TIV

DIV

TIV

Alu

TIV

CIV

DIV

Nominal

meter size

Cone

[l/h]

[Nm

3

/h]

[mbar]

DN15, ½"

K 15.1

18

25

-

0.42

0.65

-

12

21

26

-

K 15.2

30

40

-

0.7

1

-

12

21

26

-

K 15.3

55

63

-

1

1.5

-

12

21

26

-

K 15.4

80

100

-

1.7

2.2

-

12

21

26

-

K 15.5

120

160

-

2.5

3.6

-

12

21

26

-

K 15.6

200

250

-

4.2

5.5

-

12

21

26

-

K 15.7

350

400

700

6.7

10

18

1

12

21

28

38

K 15.8

500

630

1000

10

14

28

2

13

22

32

50

K 15.8

-

- 1600

3

-

-

50

3

-

-

-

85

DN25, 1"

K 25.1

480

630

1000

9.5

14

-

11

24

32

72

K 25.2

820

1000

1600

15

23

-

11

24

33

74

K 25.3

1200

1600

2500

22

35

-

11

25

34

75

K 25.4

1700

2500

4000

37

50

110

2

12

26

38

78

K 25.5

3200

4000

6300

62

95

180

2

13

30

45

103

4

DN50, 2"

K 55.1

2700

6300

8400

58

80

230

2

8

13

74

60

K 55.2

3600

10000

14000

77

110

350

2

8

13

77

69

K 55.3

5100

16000

25000

110

150

700

2

9

13

84

104

DN80, 3"

K 85.1

12000

25000

37000

245

350

1000

2

8

16

68

95

K 85.2

16000

40000

64000

280

400

1800

2

9

16

89

125

DN100, 4"

K105.1

19000

63000 100 000

-

550

2800

2

-

-

120

220

1 P >0.5 bar
2 P >0,5 bar
3 with TR float
4 300 mbar with damping (gas measurement)

INFORMATION!
The operating pressure should be at least double the pressure loss for liquids and five times for
gases. The indicated pressure losses are valid for water and air at maximum flow rate. Other
flow ranges on request. Conversion of other media or operating data is performed using the
calculation method in accordance with VDI /VDE Directive 3513.