TECHNICAL DATA

8

67

H250 M40

www.krohne.com

11/2012 - 4000640702 MA H250 M40 R02 en

ESK4-T with LCD, binary inputs and outputs and digital counter

Approvals

Binary output

Two binary outputs

Galvanically isolated, passive

Mode

Switch output

NAMUR or transistor (open

collector)

Configurable as

Switch contact or

Pulse output

Opener/NO contact or

max. 10 pulses / s

NAMUR switch output

Power supply

8,2 VDC

Signal current

> 3 mA switching value not

reached;

< 1 mA switching value

reached

Switch output transistor (open collector)

Power supply

Nominal 24 VDC, maximal 30 VDC

P

max

500 mW

Continuous current

max. 100 mA

No load current I

0

≤ 2mA

Pulse output

T

on

configurable from 50...500 ms

T

off

depending on flow rate

Pulse value

configurable in flow units e.g. 5 pulses / m

3

Binary input

Input

Galvanically isolated

Mode

Reset counters or run/stop

Configurable as

active Hi / active Lo

H- signal

16...30 VDC

Internal resistance R

i

typ. 20 kOhm

T

on

(active)

≥500 ms

Standard

Screen

Marking

ATEX /

IECEx

M40 mechanical

II2GD IIC

II3GD IIC

M40 electrical

III2G Ex ia IIC T6 Gb

II2G Ex d IIC T6 Gb

II3G Ex nA IIC T6 Gc

II2D Ex t IIIC T70°C Db

FM (USA)

FM (Canada)

M40

pending

NEPSI

M40

pending