ELECTRICAL CONNECTIONS

4

25

H250 M40

www.krohne.com

11/2012 - 4000640702 MA H250 M40 R02 en

Setting is carried out directly via contact pointers 1 and 2:

• Slide the scale away
• Loosen the locking screw 3 slightly
• Slide the scale back to the latching point
• Set contact pointers 1 and 2 to the desired switching point

After setting has been carried out: Fix the contact pointers with the locking screw 3.

Limit switch connection terminals

1 2-wire limit switch NAMUR
2 3-wire limit switch
3 Limit switch Reed SPST
4 Terminal connection min contact
5 Terminal connection max contact
6 3-wire load
7 NAMUR isolated switching amplifier
8 3-wire power supply

Limit setting

Figure 4-1: Limit switch settings

1 Contact pointer MAX
2 Contact pointer MIN
3 Locking screw

MA_H250_M40_R02_en_640702_PRT.book Page 25 Wednesday, November 28, 2012 12:23 PM