beautypg.com

Technical data, 2 technical data – KROHNE H250 M40 EN User Manual

Page 62

background image

8

TECHNICAL DATA

62

H250 M40

www.krohne.com

11/2012 - 4000640702 MA H250 M40 R02 en

8.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Flow measurement of liquids, gases and vapors

Function / Measuring principle

Variable area measuring principle

Measured value

Primary measured value

Float position

Secondary measured value

Operating and standard volumetric flow

Measuring accuracy

Directive

VDI / VDE 3513, sheet 2 (q

G

= 50%)

H250 /RR /HC /F

1.6%

H250/C (Ceramic, PTFE)

H250H, H250U, H250 (100 : 1)

2.5%

Operating conditions

Temperature

Temperature

Temperature

Temperature

Max. operating temperature TS

-196..+300°C / -321...+572°F

Pressure

Pressure

Pressure

Pressure

Max. operating pressure PS

Depending on the version, up to 400 bar / 5802 psig

1

Max. test pressure PT

Pressure equipment directive 97/23/EC or AD 2000-HP30

Min. required operating pressure

2 times greater than pressure loss (see measuring ranges)

Protection category

Protection category

Protection category

Protection category

M40, M40S, M40R

IP 66/68 acc. to EN60529, NEMA 4/4X/6 acc. to NEMA 250

M40R

IP69K acc. to DIN 40050-9

Float damping during gas measurement recommended:

Float damping during gas measurement recommended:

Float damping during gas measurement recommended:

Float damping during gas measurement recommended:

DN15...25 / ½"...1"

Operating pressure <0.3 bar / 4.4 psig

DN50...100 / 2"...4"

Operating pressure <0.2 bar / 2.9 psig

Installation conditions acc. to VDI/VDE 3513 Sheet 3

Inlet run

≥ 5 x DN

Outlet run

≥ 3 x DN

1 higher operating pressures on request

MA_H250_M40_R02_en_640702_PRT.book Page 62 Wednesday, November 28, 2012 12:23 PM