3.3.1 Tightening torques

For measuring devices with PTFE liner or ceramic liner and PTFE raised face, tighten the flange
threads with the following torques:

3.3.2 Magnetic filters

The use of magnetic filters is recommended when the medium contains particles which can be
influenced magnetically. The magnetic filter is to be installed in the flow direction upstream of
the flowmeter. Bar magnets are positioned helically in the filter to provide optimal efficiency at
low pressure loss. All of the magnets are coated individually with PTFE to protect against
corrosion. Material: 1.4571

Nominal size according to

Stud bolts

Max. torque

EN 1092-1

ASME B 16.5

EN

ASME

EN 1092-1

ASME 150 lb

DN

PN

inch

lb

150 lb

300 lb

Nm

ft*lbf

Nm

ft*lbf

15

40

½“

150/300

4x M12

4x ½"

4x ½"

9.8

7.1

5.2

3.8

25

40

1“

150/300

4x M12

4x ½"

4x 5/8“

21

15

10

7.2

50

40

2“

150/300

4x M16

4x 5/8“

8x 5/8“

57

41

41

30

80

16

3“

150/300

8x M16

4x 5/8“

8x ¾"

47

34

70

51

100

16

4“

150/300

8x M16

8x 5/8“

8x ¾"

67

48

50

36

Magnetic filters

1 Type F - fitting part with flange - overall length 100 mm
2 Type FS - fitting part without flange - overall length 50 mm

MA_H250_M40_R02_en_640702_PRT.book Page 21 Wednesday, November 28, 2012 12:23 PM