4.2.2 Status value

The meanings of the status byte (unsigned integer) are described in the following tables.

Status = bad

Status = uncertain

Quality

Quality substatus

Limits

Gr

Gr

QS

QS

QS

QS

Qu

Qu

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

0

0

= bad

0

1

= uncertain

1

0

= good (Non Cascade)

1

1

= good (Cascade) - not supported

Quality

Quality substatus

Limits

Gr

Gr

QS

QS

QS

QS

Qu

Qu

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

0

0

0

0

0

0

= non-specific

0

0

0

0

0

1

= configuration error

0

0

0

0

1

0

= not connected

0

0

0

0

1

1

= device failure

0

0

0

1

0

0

= sensor failure

0

0

0

1

0

1

= no communication (last usable value)

0

0

0

1

1

0

= no communication (no usable value)

0

0

0

1

1

1

= out of service

Quality

Quality substatus

Limits

Gr

Gr

QS

QS

QS

QS

Qu

Qu

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

0

1

0

0

0

0

= non-specific

0

1

0

0

0

1

= last usable value

0

1

0

0

1

0

= substitute-set

0

1

0

0

1

1

= initial value

0

1

0

1

0

0

= sensor conversion not accurate

0

1

0

1

0

1

= engineering unit violation (unit not in the valid set)

0

1

0

1

1

0

= sub-normal

0

1

0

1

1

1

= configuration error

0

1

1

0

0

0

= simulated value