Operation – KROHNE IFC 100 Converter FOUNDATION FIELDBUS User Manual
Page 27
OPERATION
4
27
IFC 100
www.krohne.com
02/2012 - 4001702901 - AD IFC 100 FF R01 en
UNITS_INDEX
Units Index
R/W
Device Description units code index for the engineering unit
descriptor for the associated block value.
kg/h
Setting:
g/s; g/min; g/h; g/d; kg/s; kg/min; kg/h; kg/d; t/s; t/min; t/h;
t/d; lb/s; lb/min; lb/h; lb/d; st/s = (Ston/s); st/min = (Ston/min);
st/h = (Ston/h); st/d = (Ston/d); lt/s = (LTon/s); lt/min =
(Lton/min); lt/h = (LTon/h); lt/d = (LTon/d); MLB/H
DECIMAL
Decimal
R
The number of digits to the right of the decimal point which
should be used by an interface device in displaying the
specified parameter.
0
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
TYPE_3
TYPE_3
TYPE_3
TYPE_3
Primary Value Type
R
The type of measurement represented by the primary value.
For example: mass flow, absolute pressure, differential
temperature.
flow speed
PRIMARY_VALUE_3
PRIMARY_VALUE_3
PRIMARY_VALUE_3
PRIMARY_VALUE_3
flow speed
The measured flow speed value and status available to the
function block.
-
STATUS
Status
R
Digital transducers, unlike their analogue versions, can detect
faults that make the measurement bad or prevent the
actuator from responding. This additional, valuable
information will be passed along with each transmission of a
data value in the form of a status attribute.
-
VALUE
Value
R
A numerical quantity entered by a user or calculated by the
algorithm.
-
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
RANGE_3
RANGE_3
RANGE_3
RANGE_3
flow speed range
The high and low range limit values, the engineering units
code and the number of digits to the right of the decimal point
to be used to display the "Primary Value".
-
EU_100
max value
R
The engineering unit value which represents the upper end of
range of the associated Block Parameter.
100
EU_0
min value
R
The engineering unit value which represents the lower end of
range of the associated Block Parameter.
0.0
UNITS_INDEX
Units Index
R/W
Device Description units code index for the engineering unit
descriptor for the associated block value.
m/s
Setting:
m/s; mm/s; m/h; km/h; knot; in/s; in/m; in/h; ft/s; ft/m; ft/h;
yd/s; yd/m; yd/h; MPH
DECIMAL
Decimal
R
The number of digits to the right of the decimal point which
should be used by an interface device in displaying the
specified parameter.
3
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
TYPE_4
TYPE_4
TYPE_4
TYPE_4
Primary Value Type
R
The type of measurement represented by the primary value.
For example: mass flow, absolute pressure, differential
temperature.
coil temperature
PRIMARY_VALUE_4
PRIMARY_VALUE_4
PRIMARY_VALUE_4
PRIMARY_VALUE_4
coil temperature
The measured coil temperature value and status available to
the function block.
-
STATUS
Status
R
Digital transducers, unlike their analogue versions, can detect
faults that make the measurement bad or prevent the
actuator from responding. This additional, valuable
information will be passed along with each transmission of a
data value in the form of a status attribute.
-
VALUE
Value
R
A numerical quantity entered by a user or calculated by the
algorithm.
-
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
RANGE_4
RANGE_4
RANGE_4
RANGE_4
coil temperature
range
The high and low range limit values, the engineering units
code and the number of digits to the right of the decimal point
to be used to display the "Primary Value".
-
EU_100
max value
R
The engineering unit value which represents the upper end of
range of the associated Block Parameter.
100
EU_0
min value
R
The engineering unit value which represents the lower end of
range of the associated Block Parameter.
0.0
Parameter
Parameter
Parameter
Parameter
Subelement
Access
Description and settings
Initial Value