UNITS_INDEX

Units Index

R/W

Device Description units code index for the engineering unit

descriptor for the associated block value.

kg/h

Setting:

g/s; g/min; g/h; g/d; kg/s; kg/min; kg/h; kg/d; t/s; t/min; t/h;

t/d; lb/s; lb/min; lb/h; lb/d; st/s = (Ston/s); st/min = (Ston/min);

st/h = (Ston/h); st/d = (Ston/d); lt/s = (LTon/s); lt/min =

(Lton/min); lt/h = (LTon/h); lt/d = (LTon/d); MLB/H

DECIMAL

Decimal

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

0

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

TYPE_3

TYPE_3

TYPE_3

TYPE_3

Primary Value Type

R

The type of measurement represented by the primary value.

For example: mass flow, absolute pressure, differential

temperature.

flow speed

PRIMARY_VALUE_3

PRIMARY_VALUE_3

PRIMARY_VALUE_3

PRIMARY_VALUE_3

flow speed

The measured flow speed value and status available to the

function block.

-

STATUS

Status

R

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_3

RANGE_3

RANGE_3

RANGE_3

flow speed range

The high and low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the "Primary Value".

-

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated Block Parameter.

100

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated Block Parameter.

0.0

UNITS_INDEX

Units Index

R/W

Device Description units code index for the engineering unit

descriptor for the associated block value.

m/s

Setting:

m/s; mm/s; m/h; km/h; knot; in/s; in/m; in/h; ft/s; ft/m; ft/h;

yd/s; yd/m; yd/h; MPH

DECIMAL

Decimal

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

3

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

TYPE_4

TYPE_4

TYPE_4

TYPE_4

Primary Value Type

R

The type of measurement represented by the primary value.

For example: mass flow, absolute pressure, differential

temperature.

coil temperature

PRIMARY_VALUE_4

PRIMARY_VALUE_4

PRIMARY_VALUE_4

PRIMARY_VALUE_4

coil temperature

The measured coil temperature value and status available to

the function block.

-

STATUS

Status

R

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_4

RANGE_4

RANGE_4

RANGE_4

coil temperature

range

The high and low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the "Primary Value".

-

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated Block Parameter.

100

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated Block Parameter.

0.0