B.115 SYSTem:RANGe:POWer? QUERY
SYST:RANG:POW?
Syntax:
Short Form: SYST:RANG:POW?
Long Form: SYSTem:RANGe:POWer?
Returns:
Description: Indicates one of two power ranges, low (1/10 full scale) or high for remote interface power
readback and KW meter on front panel.
B.116 SYSTem:RANGe:VOLTage COMMAND
SYST:RANG:VOLT
Syntax:
Short Form: SYST:RANG:VOLT
where
Description: Establishes full scale voltage range of remote interface voltage readback and VOLTS display
on front panel. This setting is saved in non-volatile memory and is retained for subsequent power-up.
B.117 SYSTem:RANGe:VOLTage? QUERY
SYST:RANG:VOLT?
Syntax:
Short Form: SYST:RANG:VOLT? Long Form: SYSTem:RANGe:VOLTage?
Returns:
Description: Indicates full scale voltage range for remote interface voltage readback and VOLTS display on
front panel.
B.118 SYSTem:REPLY COMMAND
SYST:REPLY
Syntax:
Short Form: SYST:REPLY
Where
Description: Turns reporting of error messages on (1) or off (0). Turns on/off reporting of error messages gener-
ated when SCPI parser analyses SCPI commands. When set to 0, If command is understood, the EL
load provides the normal or expected response. When set to 1, if command is understood, the EL load
provides the normal or expected response, followed by OK. If the command is not understood, the EL
Load responds with “##” and the appropriate error message is added to the error queue. (see PAR.
B.95 for details).
B.119 SYSTem:REPLY? QUERY
SYST:REPLY?
Syntax:
Short Form: SYST:REPLY?
Long Form: SYSTem:REPLY?
Returns:
Description: Indicates whether error message reporting is on (1) or off (0).
Caution: When the GPIB/LAN interface is installed, SYST:REPLY must be on (1). Turning
SYST:REPLY off (0) will cause all commands to take approximately 1 second to complete, and the
responses to queries will have multiple CR LF pairs in front of the actual response.
B.120 SYSTem:SERNumber? QUERY
SYST:SERN?
Syntax:
Short Form: SYST:SERN?
Long Form: SYSTem:SERNumber?
Returns:
Description: Returns unit serial number.