SERIES EL 022013

A-3

A.7

*OPC — OPERATION COMPLETE COMMAND

*OPC

Syntax:

*OPC

Description: Causes load to set status bit 0 (Operation Complete) when pending operations are complete

This command sets Standard Event Status Register bit 0 to “1” when all previous commands have
been executed and changes in output level have been completed. This command does not prevent
processing of subsequent commands, but bit 0 will not be set until all pending operations are com-
pleted. (1 = set = enable function, 0 = reset = disable function).

A.8

*OPC? — OPERATION COMPLETE QUERY

*OPC?

Syntax:

*OPC?
Return value: <1> (ASCII) placed in output queue when load has completed operation.

Description: Indicates when pending operations have been completed.When all pending operations are com-

plete (all previous commands have been executed and changes in output level have been completed)
a “1” is placed in the Output Queue. Subsequent commands are inhibited until the pending operations
are completed. *OPC? is intended to be used at the end of a command line so that the application pro-
gram can monitor the bus for data until it receives the “1” from the Output Queue.

A.9

*RST — RESET COMMAND

*RST

Syntax:

*RST

Description: Causes system reset of EL Load. *RST causes the unit to be reset as follows.

• VOLT:PROT:OVE Overvoltage protection set to rated overvoltage protection limit of the

Load.

• VOLT:PROT:UND Undervoltage protection set to 0.

• CURR:PROT Current Protection set to rated overcurrent protection limit of the load. or

load system when in Master/slave operation.

• POW:PROT Power protection set to rated overpower protection of the load or load sys-

tem when in master/slave operation.

• CURR Current set to 0.

• VOLT Voltage set to maximum voltage of load.

• POW Power set to 0.

• RES Resistance set to 1000 ohms.

• COND Conductance set to .001.

• INP Input set to off.

• MODE Mode set to current.

• SYST:REPLY set to off.

No other features are affected by *RST command.