B-17

B.92 SYSTem:COMMunicate:LAN:SUBNetmask? QUERY

SYST:COMM:LAN:SUBN

?

Syntax:

Short Form: SYST:COMM:LAN:SUBN?
Long Form: SYSTem:COMMunicate:LAN:SUBNetmask?
Returns: = numbers from 0 to 255 comprising the Subnet Mask

Description: Returns the Subnet Mask used during LAN communication.

B.93 SYSTem:DAMPing COMMAND

SYST:DAMP

Syntax:

Short Form: SYST:DAMP x

Long Form: SYSTem:DAMPing x

Where x = integer from 0 (minimum damping) to 7 (maximum damping) except units with firmware ver-
sion suffix B2 and lower accept only 0 to 5(maximum)

Description: Inserts capacitance required to damp oscillation. Increased damping reduces the tendency for

oscillation and reduces response time to high speed transients. Units shipped from the factory are
shipped with SYST:DAMP set to 4. See PAR. 3.14 for an explanation of damping as well as a recom-
mended procedure for adjusting damping.

B.94 SYSTem:DAMPing? QUERY

SYST:DAMP?

Syntax:

Short Form: SYST:DAMP?

Long Form: SYSTem:DAMPing?

Returns x where x = integer from 0 (minimum damping) to 7 (maximum damping) (5 is maximum
damping for units with firmware version suffix B2 or lower)

Description: Inserts capacitance required to damp oscillation. Factory default setting is 7 (default is 5 for units

with firmware version suffix B2 or lower). See PAR. 3.14

B.95 SYSTem:ERRor? QUERY

SYST:ERR?

Syntax:

Short Form: SYST:ERR?

Long Form: SYSTem:ERRor?

Description: Returns next entry from the error message queue. Responds with the most recent error message

in a queue of up to 10 possible messages and clears each error message as it is sent. Issuing *CLS
clears all error messages in the queue.

Error Message

Code

Command Error Generic -100
Invalid Separator

-103

Illegal Parameter Value

-224

Invalid Unit Number

-241

Queue Overflow

-350

No Error

-0

B.96 SYSTem:EXTernal COMMAND

SYST:EXT

Syntax:

Short Form: SYST:EXT

Long Form: SYSTem:EXTernal

where = 0 or OFF for disable, 1 or ON for enable

Description: Enables or disables external analog programming.

B.97 SYSTem:EXTernal? QUERY

SYST:EXT?

Syntax:

Short Form: SYST:EXT?

Long Form: SYSTem:EXTernal?

Returns: = 0 (disabled) or 1 (enabled)

Description: Indicates whether external analog programming is enabled or disabled.

B.98 SYSTem:FAN COMMAND

SYST:FAN

Syntax:

Short Form: SYST:FAN

Long Form: SYSTem:FAN

Where = integer, either 0 or 100

Description: SYST:FAN 0 sets fan to off. SYST:FAN 100 sets fan to on.