beautypg.com

B.50 [source:]resistance:transient command, B.51 [source:]resistance:transient? query, B.46 – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.87 to 3.xx User Manual

Page 72: Source, B.47, B.48, B.49, B.50, B.51, B.52

background image

B-10

SERIES EL 022013

B.46 [SOURce:]POWer:PROTection:STATe[:LEVel] COMMAND

POW:PROT:STAT 0

Syntax:

Short Form: [SOUR:]POW:PROT:STAT[:LEV] 0
Long Form: [SOURce:]POWer:PROTection:STATe[:LEVel] 0

Description: Clears power protection error.

B.47 [SOURce:]POWer:PROTection:STATe[:LEVel]? QUERY

POW:PROT:STAT?

Syntax:

Short Form: [SOUR:]POW:PROT:STAT[:LEV]?
Long Form: [SOURce:]POWer:PROTection:STATe[:LEVel]?
where: = 1 (power protection error occurred)

0 (power protection error has not occurred)

Description: Indicates whether a power protection error has occurred (1) or not (0).

B.48 [SOURce:]RESistance[:LEVel][:IMMediate][:AMPlitude] COMMAND

RES

Syntax:

Short Form: [SOUR:]RES[:LEV][:IMM][:AMP]
Long Form: [SOURce:]RESistance[:LEVel][:IMMediate][:AMPlitude]
Where: = resistance setpoint

Description: Establishes resistance setpoint. The resistance setpoint only affects the load when the load is in

Resistance mode of operation. Resistance setpoint is stored in non-volatile memory; value is restored
upon power-up.

B.49 [SOURce:]RESistance[:LEVel][:IMMediate][:AMPlitude]? QUERY

RES?

Syntax:

Short Form: [SOUR:]RES[:LEV][:IMM][:AMP]?
Long Form: [SOURce:]RESistance[:LEVel][:IMMediate][:AMPlitude]?
Returns: = resistance setpoint

Description: Indicates resistance setpoint.

B.50 [SOURce:]RESistance:TRANsient COMMAND

RES:TRAN

Syntax:

Short Form: [SOUR:]RES:TRAN ,

Description: Configures a transient resistance pulse that is initiated by SYST:MODE:TRAN (see PAR. B.100).

See PAR. B.106 for details on using both Transient and Ramp commands at the same time. Figure B-
3 on page B-20 shows tra
nsient and ramp timing.

B.51 [SOURce:]RESistance:TRANsient? QUERY

RES:TRAN?

Syntax:

Short Form: [SOUR:]RES:TRAN?
Long Form: [SOURce:]RESistance:TRANsient?
Returns: ,

Description:Returns the transient resistance pulse parameters established by RES:TRAN (see PAR. B.50).

B.52 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude] COMMAND

VOLT

Syntax:

Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]
where: = voltage setpoint

Description: Establishes voltage setpoint. The voltage setpoint only affects the load when the load is in Voltage

mode of operation. Voltage setpoint is stored in non-volatile memory; value is restored upon power-
up.