beautypg.com

10 reset, 11 operator testing, Table 3-13. revisions/test menu – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual

Page 99: Caution, Vertent activation, Reset -35, Operator testing -35, 13 revisions/test menu -35, Le 3-13)

background image

BOP HIPWR 031912

3-35

$

. Then highlight a waveform location designated Empty and press

$

to save or

%

to abort

the change and exit. The copied waveform may then be modified and saved with a new name if
desired (see PAR. 3.3.9.7).

3.3.10

RESET

CAUTION: PRESSING RESET WILL CAUSE VOLTAGE TRANSIENTS TO APPEAR AT

THE OUTPUT WHICH MAY DAMAGE A CONNECTED LOAD. SWITCH IS
RECESSED TO PREVENT INADVERTENT ACTIVATION.

Pressing RESET causes the power supply to execute a complete power on sequence to reset
the power supply to the power up settings (see PAR. 3.3.7).

3.3.11

OPERATOR TESTING

The Test System submenu is entered by pressing

%

from the power-up screen, then highlight

Revision/Test and press

!

. Upon power-up all tests are flagged as Untested. Table 3-13 lists

the tests that can be run. Highlight the choice and press

#

to run the selected test.

TABLE 3-13. REVISIONS/TEST MENU

SETTING

CHOICES

(BOLD = Factory Default)

FUNCTION

MAXIMUM OUTPUT

VOLTAGE XX

CURRENT YY

(Cannot be highlighted)

XX.0

YY.0

Displays rated output voltage and current of power supply. including all slaves
connected in parallel or series.

TEST

DISPLAY

Status (see NOTE below)

Automatic test, reports status messages (see NOTE below).

KEYPAD

Status (see NOTE below)

Requires depressing keys indicated on LCD.
This test requires pressing every key on the keypad, plus moving the
ADJUST control clockwise and counterclockwise, with the ADJUST control
depressed and released. As the keys and control function pass the tests, the
corresponding function on the LCD is highlighted. When the last test is suc-
cessful, the LCD displays “passed.” The test must be completed within two
minutes, otherwise a “Failed” indication is displayed.

INTER-

FACE

Status (see NOTE below)

Automatic test, reports status messages (see NOTE below).

SERIAL

Status (see NOTE below)

Automatic test of serial port - requires installation of loop back test connector.
(see PAR. 3.5.6.4). Reports status messages (see NOTE below).

ANALOG

Status (see NOTE below)

Automatic test which does not affect unit output. Reports status messages
(see NOTE below).

OUTPUT

Status (see NOTE below)

WARNING: DANGEROUS VOLTAGES ARE PRESENT AT THE OUTPUT
TERMINALS: DO NOT TOUCH! DISCONNECT LOAD BEFORE RUNNING
THIS TEST.
Output is automatically programmed to +

E

Onom

then –

E

Onom

,

then to 0V. Test duration is less than 2 Seconds. Reports status messages
(see NOTE below).

REVISIONS

DISPLAY

INTERFACE

ANALOG

(Cannot be highlighted)

x.xx

y.yy

z.zz

Displays current firmware revision for display, interface and analog proces-
sors.

NOTE: Test status is as follows:

UNTESTED

Initial status when first entering menu.

TESTING

Test is running.

PASSED

Test was successful.

FAILED

Test failed.

FAIL EXT