beautypg.com

B.71 [source:]list:set:sample? query, B.72 [source:]list:set:trigger command, B.73 [source:]list:set:trigger? query – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual

Page 173: B.74 [source:]list:set:wait command, B.75 [source:]list:set:wait? query, B.76 [source:]list:trigger command, B.71, Sour, B.72, B.73

background image

BOP-1K 031912

B-19

B.71 [SOURce:]LIST:SET:SAMPle? QUERY

LIST:SET:SAMP?

Syntax:

Short Form: LIST:SET:SAMP?

Long Form: LIST:SET:SAMPle?

Returns:

Description: Returns sample pulse duration. Returns sample pulse duration set by LIST:SET:SAMP command,

between 0.00025 and 0.034 Second.

If

sample pulse duration

has not been set, error 100- “com-

mand error” results.

B.72 [SOURce:]LIST:SET:TRIGger COMMAND

LIST:SET:TRIG

Syntax:

Short Form: LIST:SET:TRIG

Description: Enables the output trigger and establishes pulse-width. Used to establish EXT_C (pin 5) and

EXT_E (pin 6) of External Protection port as an output trigger instead of an output off flag. Once
LIST:SET:TRIG is sent, these pins function as an output trigger (see Table 2-4) until LIST:CLE (PAR.
B.49) is sent, restoring the function to output off flag. See Figure B-7 for example. The pulse width,
between 0.00025 to 0.034 (Seconds) is established by

B.73 [SOURce:]LIST:SET:TRIGger? QUERY

LIST:SET:TRIG?

Syntax:

Short Form: LIST:SET:TRIG?

Long Form: LIST:SET:TRIGger?

Returns = trigger pulse-width between 0.00025 and 0.034 Second

Description: Returns trigger pulse-width. If trigger pulse duration has not been set, error 100- “command error”

results

.

B.74 [SOURce:]LIST:SET:WAIT COMMAND

LIST:SET:WAIT

Syntax:

Short Form: LIST:SET:WAIT value
Long Form: LIST:SET:WAIT value
where:
= time-out for a wait command between 0.00025 and 0.034 Seconds

Description: Establishes the time-out for a wait command. If this command is not sent, the time out period will

be 0 indicating an infinite wait time. (See Figures B-6 and B-7.)

B.75 [SOURce:]LIST:SET:WAIT? QUERY

LIST:SET:WAIT?

Syntax:

Short Form: LIST:SET:WAIT?

Long Form: LIST:SET:WAIT?

Returns = time-out for a wait command between 0.00025 and 0.033 Second

Description: Returns the time-out for a wait command. Returns 0 if LIST:SET:WAIT not sent, indicating infinite wait

time.

B.76 [SOURce:]LIST:TRIGger COMMAND

LIST:TRIG

Syntax:

Short Form: LIST:TRIG
Long Form: LIST:TRIGger
where:
= programmed current (Amps) for current list, or programmed voltage (Volts) for voltage list.

Description: Similar to LIST:VOLT or LIST:CURR, except also allows Output Off flag of External Protection

Port to be used to trigger an external device. In addition to setting the output to the speci-
fied (for duration established by LIST:SET:TRIG), causes the Output Off flag transistor (EXT_E, pin 5,
and EXT_C, pin 6, of the External Protection port) to be set to the state (on or off) for the duration set
by the LIST:SET:TRIG command.

If the trigger duration is not established by the LIST:SET:TRIG command, a -221 “Settings conflict”
error results. This command must be preceded by LIST:CURR or LIST:VOLT command, otherwise a -
221 “Settings conflict” error results. The entries on the dwell list must match the values on the current
or voltage list, otherwise a -226 “Lists Not Same Length” error results. (See Figure B-7.)