beautypg.com

B.88 [source:]voltage[:level]:limit[:both] command, B.89 [source:]voltage[:level]:limit[:both]? query, B.86 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual

Page 179: Sour, B.87, B.88, B.89, B.90, B.91, B.92

background image

BOP-1K 031912

B-25

This command must be preceded by LIST:CURR or LIST:VOLT command, otherwise a -221 “Settings
Conflict” error results. The entries of the dwell list must match the values in the current or voltage list,
otherwise a -236 “Lists Unbalanced” error results. (See Figures B-6 and B-7.)

B.86 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude] COMMAND

VOLT

Syntax:

Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]
= digits with decimal point and Exponent, e.g., 2.71E1 for 27.1

Description: Sets programmed voltage level at power supply output. This command programs output voltage

to a specific value; actual output voltage will depend on load conditions. If the value exceeds the max-
imum for the model being programmed, error message -222,”Data out of range” is posted in output
queue. (See example, Figure B-1.)

B.87 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? QUERY

VOLT?

Syntax:

Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]? {MIN | MAX}
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? {MIN | MAX}

Description: Identifies programmed voltage, maximum allowable voltage, or minimum voltage. The VOLT?

query returns the programmed value of voltage. Actual output voltage will depend on load conditions.
The VOLT?MAX query returns the maximum voltage allowed for a particular model. VOLT? MIN
returns minimum voltage allowed for power supply (always negative). Related Commands: VOLT.
(See example, Figure B-1.)

B.88 [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH] COMMAND

VOLT:LIM[:BOTH]

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH]
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH]
where is between zero and rated (nominal) output voltage

Description: Establishes the software limit for output voltage, i.e., sets the maximum value of positive or

negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.

B.89 [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH]? QUERY

VOLT:LIM[:BOTH]?

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH]?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:[:BOTH]?
Returns

Description: Identifies the software limit value for both positive and negative output voltage specified by the user.

B.90 [SOURce:]VOLTage[:LEVel]:LIMit:NEGative COMMAND

VOLT:LIM:NEG

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative
where is between zero and rated (nominal) output voltage

Description: Establishes the software limit for negative output voltage, i.e., sets the maximum value of

negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.

B.91 [SOURce:]VOLTage[:LEVel]:LIMit:NEGative? QUERY

VOLT:LIM:NEG?

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative?

Description: Identifies the software limit value for negative output voltage specified by the user.

B.92 [SOURce:]VOLTage[:LEVel]:LIMit:POSitive COMMAND

VOLT:LIM:POS

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:LIM:POS
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive
where is between zero and rated (nominal) output voltage

Description: Establishes the software limit for positive output voltage, i.e., sets the maximum value of pos-

itive output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to save
for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.