B.67 [source:]list:sample:current command, B.68 [source:]list:sample:voltage command, B.69 [source:]list:sample? query – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual
Page 172: B.70 [source:]list:set:sample command, B.67, Sour, B.68, B.69, B.70, B.70, b.71
B-18
BOP-1K 031912
B.67 [SOURce:]LIST:SAMPle:CURRent COMMAND
LIST:SAMP:CURR
Syntax:
Short Form: LIST:SAMP:CURR average,value
Long Form: LIST:SAMPle:CURRent average,value
where:
Description: Samples output current.
in Volts.
permitted results in the average being set to the next lowest permitted number. The actual number of
points added to the list is age>. The timing of the first sample is not exact. The sample duration must be established by the LIST:SET:SAMP command, otherwise a -221 ”Settings conflict” error will result This command must be preceded by LIST:CURR, LIST:VOLT or LIST:SET:SAMPLE command, other- wise a -221 ”Settings conflict” error will result. The entries on the dwell list must match the values on the current or voltage list, otherwise a -226 “Not Same Length” error will result. Only eight samples may be taken in a list. If more than eight LIST:SAMP:CURR or LIST:SAMP:VOLT commands are included in the list, a -223 “Too Much data“ error results. Also, note that each sample uses one of the points in the waveform table; if the total number of points in the waveform exceeds 3933, -223 “Too Much data“ error results. (See Figures B-6 and B-7.) B.68 [SOURce:]LIST:SAMPle:VOLTage COMMAND LIST:SAMP:VOLT Syntax: Short Form: LIST:SAMP:VOLT average,value Description: Samples output voltage. in Volts. permitted results in the average being set to the next lowest permitted number. The actual number of points added to the list is age>. The timing of the first sample is not exact. The sample duration must be established by the LIST:SET:SAMP command, otherwise a -221 ”Settings conflict” error will result This command must be preceded by LIST:CURR, LIST:VOLT or LIST:SET:SAMPLE command, other- wise a -221 ”Settings conflict” error will result. The entries on the dwell list must match the values on the current or voltage list, otherwise a -226 “Not Same Length” error will result. Only eight samples may be taken in a list. If more than eight LIST:SAMP:CURR or LIST:SAMP:VOLT commands are included in the list, a -223 “Too Much data“ error results. Also, note that each sample uses one of the points in the waveform table; if the total number of points in the waveform exceeds 3933, -223 “Too Much data“ error results. (See Figures B-6 and B-7.) B.69 [SOURce:]LIST:SAMPle? QUERY LIST:SAMP? Syntax: Short Form: LIST:SAMP? Description: Returns a comma-separated list of numbers representing points, followed by V or C. The point listings are determined by the settings of LIST:SAMP:CURR and LIST:SAMP:VOLT commands. The B.70 [SOURce:]LIST:SET:SAMPle COMMAND LIST:SET:SAMP Syntax: Short Form: LIST:SET:SAMP value Description: Establishes sample pulse duration. This command must be used when measuring a sample, but must only be issued once, otherwise a -100 “command error: will result. (See Figures B-6 and B-7.)
Long Form: LIST:SAMPle:VOLTage average,value
where:
average = number of measurements = integer: 2,4,8,16,32,64,128 or 256
value = programmed current (Amps) for current list, or programmed voltage (Volts) for voltage list.
Long Form: LIST:SAMPle?
Returns:
sample(s) occur after the points indicated. The type of list is indicated by V (Voltage) or C (Current).
(See Figures B-6 and B-7.)
Long Form: LIST:SET:SAMPle value
where value = sample pulse duration, between 0.00025 and 0.034 (Seconds)