8 storing/recalling power supply output settings, Table 3-8. save/recall menu, Storing/recalling power supply output settings -23 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual
Page 87: Save/recall menu -23
BOP HIPWR 031912
3-23
3.3.8
STORING/RECALLING POWER SUPPLY OUTPUT SETTINGS
The power supply settings (mode, main channel reference type and setting, protection limit type
and setting and output status) can be stored in one of 99 memory locations for later recall. This
feature is accessible from the front panel by pressing
!
from the power-up screen to view the
Saved Settings screen (Figure 3-8). For a description of abbreviations used, refer to PAR.
3.3.8.1 To view previously saved settings refer to PAR 3.3.8.3. To save the power supply set-
tings or modify previously saved settings refer to PAR. 3.3.8.3. To recall saved settings and
apply them to the output refer to PAR. 3.3.8.5.
3.3.8.1
UNDERSTANDING ABBREVIATIONS USED FOR SAVED SETTINGS
The parameters listed in Table 3-8 are displayed, followed by a listing of the first 20 memory
locations, displayed in two rows of ten. Use
T
and
R
keys to display additional columns or
navigate to the desired location.
Locations that are not empty show an abbreviated representation of the saved settings. (To see
all the pertinent settings for a particular location, highlight the location, then press
!
; press
%
to exit without modifying the settings.)
If either Voltage or Current mode were saved, the main channel setting is listed under the Main
heading followed by V (voltage) or A (current), followed by either f (Output OFF), n (Output ON).
If the reference type is ExtRefLvl (instead of Internal or External), the uppercase V or A is
replaced by lowercase v or a. The protection setting is listed under the Prot heading.
TABLE 3-8. SAVE/RECALL MENU
PARAMETER
CHOICES
(BOLD = Factory Default)
FUNCTION
NOTE: DEFAULT values for empty cells are the settings of the unit at the time the save/recall menu is entered.
MODE
VOLT
CURRENT
EXTERNAL
VOLT - Selects voltage mode. Voltage value determined by SETTING.
CURRENT - Selects current mode. Current value determined by SETTING.
EXTERNAL - Used for customized configuration where EXT VM/CM signal at pin
2 of I/O port controls mode; consult factory for details.
MAIN CHANNEL
REFERENCE
INTERNAL
EXTERNAL
EXTL REF LVL
INTERNAL: Any external reference applied to the Analog I/O port pin 11 is ignored
and the internal reference established by SETTING field.
EXTERNAL: The internal reference is ignored, and the external reference applied
to the Analog I/O port pin 11 is used (see PAR. 3.4.3.1).
EXTL REF LVL: Allows the gain of the BOP to be established by the maximum
output voltage or current introduced by the SETTING field. (see PAR. 3.4.3.2).
SETTING
nn.nnn or
nnn.nnn
(model and parameter
dependent)
Sets the active channel setting. E.g., if VOLT mode is selected, nnn.nnn is voltage
setting, if CURRENT mode is selected, nn.nnn is current setting. If EXTERNAL
mode is selected, SETTING is not available.