beautypg.com

B.50 [source:]list:count command, B.51 [source:]list:count? query, B.50 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual

Page 168: Sour, B.51, B.50, b.51, List:coun

background image

B-14

BOP-1K 031912

B.50 [SOURce:]LIST:COUNt COMMAND

LIST:COUN

Syntax:

Short Form: LIST:COUN Long Form: LIST:COUNt>

Description: Establishes how many times the list is executed. Allows user to establish how many times the list

is executed. For LIST:COUN 0, the unit will execute the sequence indefinitely until a VOLT:MODE
FIXED, command is received. (See example, Figure B-5.)

B.51 [SOURce:]LIST:COUNt? QUERY

LIST:COUN?

Syntax:

Short Form: LIST:COUNT?

Long Form: LIST:COUNt?

Return Value:

Description: Identifies how many times the list will be executed. Returns value set by LIST:COUN command.

(See example, Figure B-5.)

FIGURE B-5. USING LIST COMMANDS AND QUERIES (SHEET 2 OF 2)

.VOLT:MODE LIST

Executes the list. For 240 mS the BOP outputs a staircase triangle wave
from -20V to +20V and back down to -20V. This staircase will have a uni-
form spacing between voltage changes of 10 mS and will repeat 100 times.

VOLT?

Returns +20 (the last step in the list set the unit to +20V.

LIST:COUNT?

Returns 100.

LIST:COUNT 10

Determines that the list will be repeated 10 times when executed.

LIST:COUNT?

Returns 10.

VOLT:MODE LIST

Initiates execution of the list. The unit outputs a sawtooth waveform that
increases from -20V to +20V and repeats 10 times. There is an abrupt
change from +20V to -20V each time the list transitions from location 20 to
location 0.

VOLT?

Returns 20, (the last step in the list set the unit to 20V.

LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01

Enters dwell time of 0.01 Seconds in locations 1 through 9.

LIST:DWELL .03

Enters dwell time of 0.03 Second in location 10.

VOLT:MODE LIST

the list is not executed, the unit returns error -221,Settings Error indicating
the lists are not balanced.

LIST:DWELL:POINTS?

Returns 11 to indicate the dwell list has 11 entries

LIST:VOLT:POINTS?

Returns 21 to indicate the voltage list has 21 entries.

LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01,.01

Dwell times are entered in locations 11 through 20.

DWELL:POINTS?

Returns 21 indicating there are now 21 step dwell times on the list.

LIST:QUER?

Returns 0 indicating list queries will start from location 0

LIST:QUER 9

Causes list queries to start at location 9

LIST:DWEL?

Returns 01,.03,.01,.01,.01,.01,.01,.01,.01,.01,.01,.01(the dwell times for
locations 9 through 20.

LIST COUNT 0

List will repeat indefinitely.

VOLT:MODE LIST

The list is executed. Stair case wave now consists of 21 steps of 0.01 Sec-
onds except for the 0V step (location 10) which outputs 0V for 0.03 Second.

LIST:DWEL?

Returns error -221,Settings Error because a LIST command cannot be exe-
cuted while the LIST is still being executed.

VOLT:MODE FIX

Stops execution of the list

LIST:VOLT:APPLY SINE,60,20 Adds a 60Hz, 20V p-p sine wave to the current waveform
VOLT:MODE:LIST

Unit outputs the staircase and then the sine wave.

*RST

Unit stops generating the waveform.