B.34, Sour, B.35 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.3.05 to 4.07 User Manual
Page 165: B.36, B.37, B.38, B.39, B.40, B.35, b.33, B.37, b.38
BOP-1K 031912
B-11
B.34 [SOURce:]CURRent[:LEVel]:PROTect:NEGative? QUERY
CURR:PROT:NEG?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:NEG?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:NEGative?
Returns
Description: Identifies the negative protection limit for current.
B.35 [SOURce:]CURRent[:LEVel]:PROTect:POSitive COMMAND
CURR:PROT:POS
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:POS
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:POSitive
where
current.
Description: Establishes the positive protection limit for current, maximum is 1% greater than rated output current.
B.36 [SOURce:]CURRent[:LEVel]:PROTect:POSitive? QUERY
CURR:PROT:POS?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:POS?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:POSitive?
Returns
Description: Identifies the positive protection limit for current.
B.37 [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH] COMMAND
CURR:PROT:LIM[:BOTH]
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM[:BOTH]
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:[BOTH
where
current.
Description: Establishes the maximum value possible for both the positive and negative protection limits for cur-
rent. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR. 3.5.2.2 and Figure 3-16 for
special programming considerations.
B.38 [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH]? QUERY
CURR:PROT:LIM:[:BOTH]?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM[:BOTH]?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH]?
Returns
Description: Identifies the maximum value possible for protection limits for current (positive, negative); maximum is
1% greater than rated output current.
B.39 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative COMMAND
CURR:PROT:LIM:NEG
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:NEG
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative
where
current.
Description: Establishes the minimum (maximum absolute) value possible for the negative protection limit for cur-
rent. This may be set up to 1% greater than rated current. Requires MEM:UPD (PAR. B.12) to save for
power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.40 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative? QUERY
CURR:PROT:LIM:NEG?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:NEG?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative?
Returns:
Description: Identifies the minimum (maximum absolute) value possible for the negative protection limit for current.