B.89 SYSTem:SECurity:IMMediate COMMAND

SYST:SEC:IMM

Syntax:

Short Form: SYST:SEC:IMM

Long Form: SYSTem:SECurity:IMMediate

Description: Initializes all NVRAM variables to factory defaults. Empties all memory locations.

FIGURE B-7. SETTING THE UNIT TO REMOTE MODE VIA SERIAL (RS 232) PORT

TABLE B-6. ERROR MESSAGES

ERROR MESSAGE

ESR ERROR BIT SET

(SEE PAR. A.5)

EXPLANATION

0,“No error”

None

No error

-100,“Command error”

Command Error bit 5

Command and data understood, but more information included which is
not recognized.

-120,”Numeric data error”

Command Error bit 5 Expected number but other characters were detected.

-203,”Command Protected”

Execution error bit 4 Password must be CENAbled.

-221,”Settings Conflict”

Execution error bit 4

Calibration state not enabled but CALibrate command received; or
LIST:DIR set to DOWN.

-222,“Current, Voltage or
Data out of range”

Execution error bit 4

Value (current or voltage) exceeds power supply rating or (data)
exceeds acceptable command parameters.

-223,“Too Much Data”

Execution error bit 4

During a LIST command, the list became full, preventing all the data
from being added to the list.

-226,“Lists not same length”

Execution error bit 4

During a LIST command, number of DWEL list entries was not equal to
1 and did not match number of LIST:VOLT or LIST:CURR entries.

-240,“Hardware error”

Execution error bit 4 Power supply did not respond to command.

-301,”Voltage Error”

Device Error bit 3

(1)

Voltage output not within error window; unit set to output off -- only valid
for DIAG:ERR 1, 2 or 3 mode (see PAR. 4.7.1 and Table 4-5).

-302,”Current Error”

Device Error bit 3

(1)

Current output not within error window; unit set to output off -- only valid
for DIAG:ERR 1, 2 or 3 mode (see PAR. 4.7.1 and Table 4-6).

-311,”Memory Error”

Device Error bit 3

(1)

*SAV (save), *RCL (recall), or CALibrate:STORe error.

-350,”Queue Overflow”

Device Error bit 3

(1)

Error queue was full, error events have been lost.

-400,”QueryError”

Query Error bit 2

Data requested was lost due to 253 character limit of BIT 4886 output
buffer.

-420,”Query Unterminated”

Query Error bit 2

Controller sent query but did not accept data from power supply. See
VOLT? (PAR. B.58), CAL:SAVE (PAR. B.58) commands

(1)

The Device error bit may be set when the status monitoring functions of the power supply detect an overvoltage/undervolt-

age condition.

*IDN?

Unit responds with KEPCO,BOP 20-20,E1234,1.66 (typical).

OUTP?

Unit responds with 0 indicating output is off

SYST:REM?

Unit responds with 0 indicating unit is in local mode.

SYST:REM 1

PUTS UNIT IN REMOTE MODE.

OUTP ON

Enables output

OUTP?

Unit responds with 1 (output on).

SYST:REM 0