beautypg.com

2 enhanced operation, 3 specifications, Enhanced operation -2 – KEPCO BIT 4886 Operator Manual User Manual

Page 12: Specifications -2

background image

1-2

BIT 4886 OPR 120413

1.2.2

ENHANCED OPERATION

The BIT 4886 card includes the following enhanced operation features: a) advanced control
over the way the unit responds to errors (PAR. 4.7.1), b) advanced limit channel control for
applications such as battery, photocell, and large inductor applications (see PAR. 4.7.2) and c)
ability to save system settings (PAR. 4.7.3).

1.3

SPECIFICATIONS

For voltage and current accuracy specifications of BOP Models with a BIT 4886 card installed,
refer to Tables 1-2 and 1-3, respectively. Table 1-4 lists the specifications for the BIT 4886 card.

TABLE 1-2. BOP VOLTAGE SPECIFICATIONS WITH BIT 4886 INSTALLED

VOLTAGE

SPECIFICATION

BOP 200-1

BOP 100-1M
BOP 100-2M
BOP 100-4M

BOP 72-3M
BOP 72-6M

BOP 50-2M

BOP50-4M

BOP 50-8M

BOP 36-6M

BOP 36-12

BOP 20-5M

BOP20-10M
BOP20-20M

High range accuracy

24mV

12mV

8mV

6mV

4mV

2.4mV

Low Range Accuracy

1

6mV

3mV

2mV

1.5mV

1mV

0.6mV

Positive Limit Accuracy

2

300mV

150mV

100mV

90mV

75mV

36mV

Measurement Accuracy

120mV

60mV

45mV

30mV

24mV

12mV

NOTES: 1. Low range is defined as less than 1/4 of the rated value.

2. Positive limit accuracy applies to limit values from nominal to 2% of nominal voltage value. Negative limit accuracy

is not more than 1.0% of nominal value for voltage.

TABLE 1-3. BOP CURRENT SPECIFICATIONS WITH BIT 4886 INSTALLED

CURRENT

SPECIFICATION

BOP MODEL (ARRANGED BY CURRENT CAPABILITY)

20-20M 36-12M

20-10M

50-8M

36-6M
72-6M

20-5M

50-4M

100-4M

72-3M

50-2M

100-2M

100-1M
200-1M

High range accuracy

1

20mA

6mA

5mA

4mA

1.2mA

1mA

0.5mA

0.36mA

0.25mA

0.12mA

Low Range Accuracy

1, 2

1.6mA

0.5mA

0.3mA

0.25mA

0.2mA

0.15mA

0.12mA 0.08mA

0.06mA

0.03mA

Positive Limit Accuracy

1, 3

40mA

28mA

24mA

20mA

6mA

5mA

8mA

3mA

2mA

1mA

Measurement Accuracy

1

20mA

14mA

12mA

5mA

3mA

2.5mA

2mA

1.5mA

1mA

0.5mA

NOTES: 1. Accuracy specifications apply only after 1 minute warm-up.

2. Low range is defined as less than 1/4 of the rated value
3. Positive limit accuracy is valid from 25% to 100% of IO nominal. Negative limit accuracy is not more than 2% of nominal

value for current.