beautypg.com

5 rs232-c operation, Rs232-c operation -10, Ieee 488 (gpib) bus command mode messages -10 – KEPCO BIT 4886 Operator Manual User Manual

Page 44

background image

4-10

BIT 4886 120413

These messages are enabled during the “handshake” cycle, with the Interface Card operating
as either a Talker or a Listener.

4.5

RS232-C OPERATION

The BIT 4886 card allows the BOP to be operated via an RS232-C terminal, or from a PC using
a terminal emulation program. The default settings are as follows:

• Baud rate: 9600

• Parity:

None

• Data Bits

8

• Stop Bits

1

• Echo

ON

• XON

OFF

To change echo or XON/XOFF, refer to PAR. 4.5.2.

TABLE 4-3. IEEE 488 (GPIB) BUS COMMAND MODE MESSAGES

MNEMONIC

MESSAGE DESCRIPTION

COMMENTS

ATN

Attention

Received

DAC

Data accepted

Received or Sent

DAV

Data Valid

Received or Sent

DCL

Device Clear

Received

GET

Group Executive Trigger

Received

IFC

Interface Clear

Received

MLA

My Listen Address

Received

MTA

My Talk Address

Received

OTA

Other Talk Address

Received

RFD

Ready for Data

Received or Sent

SDC

Selected Device Clear

Received

SPD

Serial Poll Disable

Received

SPE

Serial Poll Enable

Received

SRQ

Service Request

Sent

UNL

Unlisten

Received

UNT

Untalk

Received