3 product specifications, Rugged troll 100 and 200 specifications, Product specifications – In-Situ Rugged TROLL 100/200 Operators Manual User Manual
Page 6
800-446-7488
6
www.in-situ.com
Product Specifications
Rugged TROLL 100 and 200 Specifications
General
Rugged TROLL 100 and 200
Temperature ranges
1
Operational: 0 to 50° C (32-122° F)
Storage: -40-80° C (-40-176° F)
Calibrated: 0-50° C (32-122° F)
Diameter
2.62 cm (1.03 in.)
Length
14.43 cm (5.68 in.)
Weight
170 g (0.37 lb)
Materials
Titanium body; Delrin nose cone, hanger, backend
Output options
Rugged TROLL 100: USB or RS232 via docking station
Rugged TROLL 200: USB or RS232 via docking station; Modbus/RS485 or
SDI-12 via Rugged TROLL 200 Cable
Battery type & life
2
3.6 V lithium; 10 years or 2M readings
External power
Rugged TROLL 100: NA
Rugged TROLL 200: 8-36 VDC
Memory
Data records
3
Data logs
1.0 MB
65,000
Rugged TROLL 100: 1 log; Rugged TROLL 200: 2 logs
Fastest logging rate
1 per second
Fastest output rate
Rugged TROLL 200 only: Modbus & SDI-12: 1 per second
Log types
Linear, Fast Linear, and Event
Sensor Type/Material
Piezoresistive; Ceramic
Range
9.0 m (30 ft) (Burst: 18 m; 60 ft)
30 m (100 ft) (Burst: 40 m; 134 ft)
76 m (250 ft) (Burst: 112 m; 368 ft)
Accuracy (FS)
4
±0.1% full scale (FS) typical
±0.3% FS max.
Resolution
±0.01% FS or better
Units of measure
Pressure: psi, kPa, bar, mbar, mmHg, inHg
Level: in, ft, mm, cm, m
Temperature Sensor
Accuracy
±0.3° C
Resolution
0.01° C or better
Units of measure
Celsius or Fahrenheit
Warranty
2 years
Footnotes
1
Temperature range for non-freezing liquids
2
Typical battery life when used within the factory-calibrated temperature range
3
1 data record = date/time plus 2 parameters logged (no wrapping) from device
within the factory-calibrated temperature range
4
Across factory-calibrated pressure and temperature ranges
Specifications are subject to change without notice.
Delrin is a registered trademark of E.I. du Pont de Nemours and Company.