View twa and peak – Detcon SmartWireless CXT User Manual
Page 32

Sentinel CXT
Sentinel CXT Instruction Manual
Rev. 1.5
Page 28 of 42
9. Swipe the magnet over the markers of the up or down arrows to move the arrow prompt to the
desired field.
10. A swipe over the ENTER marker will select the field indicated by the arrow prompt and the value
can be changed by swiping over the markers of the up or down arrows.
11. Another swipe over the ENTER marker will save the selected value.
12. Once the desired values have been set, move the arrow prompt to "Change Date" and swipe the
ENTER marker to update the date with the changes entered.
13. A swipe of the PROG marker at any time while setting the time or date will escape out of the
current menu with no changes saved.
5.4.7
View TWA and Peak
1. Verify that a secure digital (SD) memory card is installed in the SD slot of the CXT controller
board (J9).
2. Upon entering this menu, the user can view the data recorded from the SD card and is displayed as:
MM/DD/YY, HH:MM:SS, Channel #, TWA #, PEAK #
Example:
TWA_P08.CSV:
05/17/11,23:00:09,17,
51, 100
The sensor readings are continuously logged to the SD card. This data can also be viewed by removing the
SD card (Section 6) and inserting it in a laptop using the Detcon Log File Viewer application. Refer to the
Detcon Log File Viewer instruction manual for detailed information.