Sentinel CXT

Sentinel CXT Instruction Manual

Rev. 1.5

Page 13 of 42

3. Installation

3.1 Initial Setup

The Detcon tripod (P/N 975-TRIPOD-100) provides a stable and mobile base for the SmartWireless®
CXT. A maximum of two sensors can be secured to the tripod using Detcon brackets (P/N 943-004413-
000) installed on the tripod.

1. Unpack the tripod, open the legs and place on a level surface. The tripod must have the 3 legs

extended to widest position possible and be locked in place. The tripod must be firmly located on
level terrain or this is an extreme safety risk of the unit tipping over and causing personnel harm or
equipment damage. As is possible, the points of the tripod legs should be equally plunged into the
ground to make the tripod most firmly stabilized.

CAUTION

The tripod must have the 3 legs extended to widest position possible and be locked
in place. It then shall be firmly located on level terrain or there is an extreme safety
risk of the unit tipping over and causing personnel harm and/or equipment damage.

2. Mount the CXT to the center pipe using the supplied U-bolts in accordance with Figure 10. The

height position should be about 4-5 feet maximum to minimize tip-over potential. The U-bolts
should be thoroughly tightened such that there is no vertical slide of the controller up or down the
tripod center pipe. If it slides it may be a safety issue related to personnel injury.

CAUTION

The installed height position should be 4-5 feet maximum to minimize tip-over
potential. The U-bolts should be thoroughly tightened so there is no chance for
vertical slide of the controller up or down the tripod center pipe. If it slides
unexpectedly it is a safety issue related to personnel injury and/or tipping over.

NOTE

Position the CXT controller on the tripod and position the tripod such that all disconnecting
devices are readily accessible.

1. Install the 8" antenna onto the antenna connector on the top right side of the CXT controller (Figure

1).

2. Secure the antenna cover over the antenna.

3. If wired gas sensors are being used with the controller, attach the sensor mounting brackets to the

tripod legs using the supplied

1

/

4

" bolts, nuts and lock washers in accordance with Figure 11.

4. Secure the sensors to the brackets welded onto the tripod using the hook and pin supplied with the

bracket.

5. Connect sensor cables to the sensor ports on the CXT (Figure 1).