beautypg.com

Important addresses – AW Gear Meters EMO-1005 User Manual

Page 35

background image

AW-Lake Company 8809 Industrial Drive, Franksville, WI 53126  web: www.awgearmeters.com

 Tel: 262-884-9800  Fax: 262-884-9810  Email: [email protected]

REV. 1a 05/98 EMO-1005 Manual.DOC

34

WARNING --- IMPORTANT --- WARNING --- IMPORTANT --- WARNING
The communication port does not discriminate any addresses. This means that any address can be
written to as well read from. Certain addresses will change the operation of the EMO-1005
drastically. Caution is recommended. Double check your programming.

IMPORTANT ADDRESSES









The bytes are always arranged such that the low byte is first and then the more significant byte.

Example: the Totalizer is at 0063 0064 0065 0066 LSB MSB

Address
In HEX

Number
of Bytes

Description

0053

2

Transparent Analog Register

0055

2

Analog Output

0063

4

Totalizer (In impulses)

0067

3

Frequency Instant (In 0.00 Hz)

006A

1

Analog Input, 00=0V, FF=5V

006B

3

Peak Frequency (In 0.00 Hz)

006F

3

Frequency Mellow (In 0.00 Hz)

0074

1

Analog Output Offset

0075

1

Mode selector: 01=Mon, 02=PID, 03=Gun-On

04=Trans, 05= Ratio

0076

1

Display Cut Off Frequency

0077

1

Sample amount for Mellow Frequency

0078

3

Flow Limit 1 (In 0.00 Hz)

007B

3

Flow Limit 2 (In 0.00 Hz)

007E

3

Flow Limit 3 (In 0.00 Hz)

0081

3

Flow Limit 4 (In 0.00 Hz)

0084

4

Total Limit 1 (in impulses)

0088

4

Total Limit 2 (in impulses)

008C

4

Total Limit 3 (in impulses)

0090

4

Total Limit 4 (in impulses)

0094

2

Analog Output Gain

009B

2

Analog Input Gain

009D

1

Linearizer Activator, FF=active

009E

3

Point 1 Linearizer (In 0.00 Hz)

00A1

1

Point 1 error, E3h=-10%, 7Fh=0%, 1Bh=+10%

009E

3

Point 2 Linearizer

00A1

1

Point 2 error, E3h=-10%, 7Fh=0%, 1Bh=+10%

......

.

.........................................................................

00C2

3

Point 10 Linearizer

00C5

1

Point 10 error, E3h=-10%, 7Fh=0%, 1Bh=+10%