Important addresses – AW Gear Meters EMO-1005 User Manual
Page 35

AW-Lake Company 8809 Industrial Drive, Franksville, WI 53126 web: www.awgearmeters.com
Tel: 262-884-9800 Fax: 262-884-9810 Email: [email protected]
REV. 1a 05/98 EMO-1005 Manual.DOC
34
WARNING --- IMPORTANT --- WARNING --- IMPORTANT --- WARNING
The communication port does not discriminate any addresses. This means that any address can be
written to as well read from. Certain addresses will change the operation of the EMO-1005
drastically. Caution is recommended. Double check your programming.
IMPORTANT ADDRESSES
The bytes are always arranged such that the low byte is first and then the more significant byte.
Example: the Totalizer is at 0063 0064 0065 0066 LSB MSB
Address
In HEX
Number
of Bytes
Description
0053
2
Transparent Analog Register
0055
2
Analog Output
0063
4
Totalizer (In impulses)
0067
3
Frequency Instant (In 0.00 Hz)
006A
1
Analog Input, 00=0V, FF=5V
006B
3
Peak Frequency (In 0.00 Hz)
006F
3
Frequency Mellow (In 0.00 Hz)
0074
1
Analog Output Offset
0075
1
Mode selector: 01=Mon, 02=PID, 03=Gun-On
04=Trans, 05= Ratio
0076
1
Display Cut Off Frequency
0077
1
Sample amount for Mellow Frequency
0078
3
Flow Limit 1 (In 0.00 Hz)
007B
3
Flow Limit 2 (In 0.00 Hz)
007E
3
Flow Limit 3 (In 0.00 Hz)
0081
3
Flow Limit 4 (In 0.00 Hz)
0084
4
Total Limit 1 (in impulses)
0088
4
Total Limit 2 (in impulses)
008C
4
Total Limit 3 (in impulses)
0090
4
Total Limit 4 (in impulses)
0094
2
Analog Output Gain
009B
2
Analog Input Gain
009D
1
Linearizer Activator, FF=active
009E
3
Point 1 Linearizer (In 0.00 Hz)
00A1
1
Point 1 error, E3h=-10%, 7Fh=0%, 1Bh=+10%
009E
3
Point 2 Linearizer
00A1
1
Point 2 error, E3h=-10%, 7Fh=0%, 1Bh=+10%
......
.
.........................................................................
00C2
3
Point 10 Linearizer
00C5
1
Point 10 error, E3h=-10%, 7Fh=0%, 1Bh=+10%