Programming the emo-1005 – AW Gear Meters EMO-1005 User Manual
Page 11
AW-Lake Company 8809 Industrial Drive, Franksville, WI 53126 web: www.awgearmeters.com
Tel: 262-884-9800 Fax: 262-884-9810 Email: [email protected]
REV. 1a 05/98 EMO-1005 Manual.DOC
10
PROGRAMMING THE EMO-1005
To enter the programming mode press the following key sequence:
CHA
->
DP
->
ENT
->
KFA
Now the display will show:
LINE 1
PROGRAMMING
LINE 2
0 = NO 1 = YES
If this screen did not come up then try the key sequence once more (press
slowly and firmly on the keys). If you would like to program press the 1 key;
if not, press the 0 key. Pressing the 0 key returns the unit to the normal
operating mode. If a 1 was pushed the following screen will appear:
LINE 1
ENTER CHANNEL
LINE 2
NUMBER=??
Enter the channel number that should be programmed and press the ENT key.
NOTE: Channel 1 = 01, 2 = 02 ....
Any mistakes made during programming in the next steps must be edited while at that screen. After
leaving any display you must toggle through the remaining displays to return to the operating screen
display. Then enter the programming mode again and toggle through until you get to the screen where
you want to edit the entered value.
Before entering any new data in any of the programmable parameters, zero out the old data first.
Then start to enter the new number. The numbers will be shifted to left as they are entered.