Rate, total and grand total scaling, K-factor (scaling factor), Rate unit – AW Gear Meters MX 9000 User Manual
Page 24: Mx 9000 process monitor
MX 9000 Process Monitor
Operation and Programming Manual
23
MX 9000 User Manual, Rev. 2.0 7/16/2013
Once a character has been changed press the
SELECT
button to move to the next character to the right.
If at the right most character, pressing
SELECT
will bring the cursor back to the left most character.
If a value has a decimal point whose position can be changed, press the
SELECT
button until the
underscore is under the decimal point. Press the
DOWN
button to move the decimal point to the left
and press the
UP
button to move the decimal point to the right. NOTE: Not all programming screens
allow the decimal point location to be changed such as any milliamp value.
Once a variable has been changed to the desired value, press the
ENTER
button to accept the value and
move to the next screen or programming value. If an incorrect value is programmed, a warning or error
screen will appear. Press any button to exit a warning screen, but you must correct an error before
moving on.
RATE, TOTAL and GRAND TOTAL Scaling
Analog Menu
Figure 11: Rate, Total and Grand Total Scaling
K-factor (scaling factor)
The MX 9000 uses one K-factor for each channel for scaling displays. This value is always entered in
units of Pulses per Gallon. Once the rate and total units are selected, the MX 9000 uses internal
calculations to automatically correct the displayed values to match the user selected units. When the
correct K-factor value has been programmed, press
ENTER
to continue.
RATE unit
Use the
UP
and
DOWN
buttons to scroll through the available units to scale the RATE screen.
The available units are:
GAL
(US gallons)
LIT
(Liters)
CC
(Cubic centimeters)
BBL
(Barrels)
ML
(Milliliters)
M3
(Cubic meters)
OZ
(Liquid ounces)
PUL
(Pulses)
Once the desired unit is showing, press
ENTER
to continue.
Enter K-Factor A in
Pulses Per Gallon
123456.789
Select Rate A Units
> GAL
Sel ect Rate A Time Bas
> Minutes
Sel ect TOTAL A Units
GAL
Enter K-Factor B in
Pulses Per Gallon
123456.789
Select Rate B Units
> GAL
Sel ect Rate A Time Bas
> Minutes
Sel ect TOTAL B Units
GAL
Ra te / Total Scaling?
NO YES
EXIT