beautypg.com

Seed Hawk AIRCART 2015 User Manual

Page 83

background image

SEED HAWK

®

2015 AIRCART OPERATOR’S MANUAL

78

Possible Cause

Solution

No hydraulic pressure.

Engage hydraulic circuit (wing down).

Product control switch is
off.

Turn product control switch to auto.

Roller is jammed.

Remove roller from meter body and remove
obstruction from meter.

Check air cart node.

Check lights on front of node.

Check meter settings.

Make sure that the meter cal and cal weight is

entered correctly.

Possible Cause

Solution

No field boundry recorded. Create a field boundry.
Agressiveness is on.

Turn aggressiveness off.

Improper look aheads.

Adjust look ahead time.

Possible Cause

Solution

No field boundry recorded. Create a field boundry.
Agressiveness is on.

Turn aggressiveness off.

Improper look aheads.

Adjust look ahead time.

Possible Cause

Solution

No hydraulic pressure.

Check and re-align sensor if necessary.

Product control switch is

off.

Set fan cal to 2.

Check air cart node.

Set diverter to the fan position

Possible Cause

Solution

Speed settings set incor-
rectly

Check speed calibration settings on Loup III or
Viper Pro™.

Meter Roller Won’t Turn

Outer Opener Sections Engage When Turning

Meter Gate Alarms Going Off

No Fan Speed

No Tractor Speed