4.4.2 Operating the Conveyor
4.4.3 Conveyor Position for Unloading Aircart
1. Ensure that all screens and shrouds
are in place and that cleanout gate on
each meter is closed.
2. Activate tractor hydraulic circuit
#4, and pull the diverter valve up to
the auger circuit.
3. Use either of the buttons located
at the top and bottom of the convey-
or to start and stop the conveyor.
1. Using the remote, rotate the con-
veyor hopper under any of the aircart
compartments in order to empty
them.
2. Loosen the cross thumb-nuts on
the cleanout gate, and slide it up to
allow product to fall between the
airstream tubes.
3. Once emptied, the bottom airstream door can be removed for complete
cleanout below the meter.
NOTE: Whether filling or
unloading the Aircart, the
auger performs at its highest
capacity when product is fall-
ing directly into the flighting.