9.0 Troubleshooting SCT

®

Equipped Machines

Possible Cause

Solution

No hydraulic pressure to
meter block.

Engage hydraulic circuit (Opener).

BFJ (pressure relief block)
set too low.

Increase pressure (factory set to 1800 psi).

No power at coils.

Turn master switch on.
Check fuses.
Check connections at coil and SCT

®

node.

Possible Cause

Solution

No hydraulic pressure.

Engage hydraulic circuit (wing down).

Master switch on.

Turn master switch off (unfold only).

Gates will not open/close

Openers will not lift

Wing down switch will not work

Possible Cause

Solution

No hydraulic pressure to

meter block.

Engage hydraulic circuit (wing down).
Check green banded hydraulic connections at
drill and tractor to ensure they are properly
engaged and/or failed.

Check SCT

®

node.

Check lights on front of node.

Meter block PRV (pressure

relief valve) set to low.

Increase PRV pressure until gates cycle (do not

exceed 500 psi).

No power at coils.

Turn master switch on.
Check fuses.

Check connections at coil and SCT

®

node.

Possible Cause

Solution

Improper look aheads.

Ensure that the look ahead number is not a
negative number.

Aggressiveness set too
high.

Turn aggressiveness off.

Improper drill setup.

Wrong drill and tractor measurements in Viper
Pro™ check and adjust settings as required

Random Opener Sections Lifting